• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Connecting to the network information pack
Connecting to the network information pack

... information is provided to Essential Energy at all times, otherwise delays in connection may occur. In addition to advising of the intent to connect new premises, or carry out a connection alteration at existing premises, the Application for Low Voltage Connection Form requires the Applicant to conf ...
Transformer Calculations
Transformer Calculations

Conditions for Setting the DTC
Conditions for Setting the DTC

... • The EBCM automatically clears the history DTC when a current DTC is not detected in 100 consecutive drive cycles. Diagnostic Aids • Find out from the driver under what conditions the DTC was set. This information will help to duplicate the failure. • The Snapshot function on the scan tool can help ...
Full Glossary - Cristek Interconnects, Inc.
Full Glossary - Cristek Interconnects, Inc.

... BOARD THICKNESS The thickness of the metal-clad base material of the PC board, including conductive layer or layers. Can include additional platings and coatings depending upon when the measurement is made. BODY Main portion of a connector to which contacts and other components are attached. Typical ...
Cooper: Form 6 Part 2
Cooper: Form 6 Part 2

SEE MARKED UP PLANS FOR CLARIFICATIONS OF
SEE MARKED UP PLANS FOR CLARIFICATIONS OF

... Provide receptacle outlets wherever cord connected equipment will be used. ___________________ (210.50(B)) Conductors of a multi-wire branch circuit shall originate from the same panelboard. The branch circuit shall be provided with a means that will simultaneously disconnect all ungrounded conducto ...
Trombetta Product Guide 2014
Trombetta Product Guide 2014

... Trombetta is a leading worldwide manufacturer of DC power switching and power management products for mobile applications. Trombetta, founded in 1932 has manufacturing operations in Milwaukee WI, Malden MA, Tijuana MX and Wuxi, China. Trombetta’s products include DC Contactors, Industrial Work Solen ...
Jay Jamali - NFPA 70E
Jay Jamali - NFPA 70E

... complying with the safety-related work practices. –  New technology, new types of equipment, or changes in procedures necessitate the use of safety-related work practices that are different from those that the employee would normally use. –  The employee must employ safety-related work practices tha ...
installation manual
installation manual

FM3 Microcontroller Low Voltage Detect Interrupt Circuit Setting/Usage
FM3 Microcontroller Low Voltage Detect Interrupt Circuit Setting/Usage

Breakdown Voltage Performances of Aluminum and
Breakdown Voltage Performances of Aluminum and

... effective process monitoring have provided some level of risk mitigation, but the conductor wire is still susceptible to damage. In the wire manufacturing process, the conductor wire is extruded to acquire the correct diameter, and then dipped in an epoxy insulation to encapsulate the pure metal. T ...
pdf manual - Acoustic Dimension
pdf manual - Acoustic Dimension

... Of final concern is if the DAC used has single ended or balanced outputs. If the DAC has only Single Ended outputs it is not possible to get a balanced output signal. Conversely, DAC’s that have a balanced output can generally be connected in single ended mode with little or no complications. In the ...
Filaments Detection Circuit
Filaments Detection Circuit

Loading Considerations when Paralleling Transformers
Loading Considerations when Paralleling Transformers

... Seldom are transformers in industrial and commercial facilities connected to one common bus with different kVA and unequal percent impedances. However, there may be that one situation where two single-ended substations may be tied together via bussing or cables to provide better voltage support when ...
PolySurg Cover
PolySurg Cover

TDC3000X Galvanic Isolation/Intrinsic Safety Field Termination
TDC3000X Galvanic Isolation/Intrinsic Safety Field Termination

Surge Protection Done Right
Surge Protection Done Right

... tor within the diode bridge. The capacitor within the bridge integrates the incoming surge voltage, controlling the peak let-through voltage, dv/dt, and offering a measurement of the residual surge energy (1/2C∆V2) passing through the inductor. A very large dv/dt developed across this large capacito ...
mv controller
mv controller

... Store and handle in strict compliance with manufacturer’s instructions and recommendations. Protect from potential damage from weather and construction operations. Store so condensation will not form on or in controller, and if necessary, apply temporary heat where required to obtain suitable servic ...
IB-51802 PowlVac ITE-HK Remote Racking Device
IB-51802 PowlVac ITE-HK Remote Racking Device

... Ch 1 General Information, A. Scope. The illustrations contained in this document may not represent the exact construction details of each particular type of replacement circuit breaker. The illustrations in this document are provided as general information to aid in showing component locations only. ...
Form Factors, Power Supplies, and Working Inside a Computer
Form Factors, Power Supplies, and Working Inside a Computer

... AND POWER SUPPLIES A+ ...
Negotiated Customer Connection Contract
Negotiated Customer Connection Contract

... 4.1.2 circuit breakers provided to isolate the Customer’s facilities from Energex’s facilities are capable of breaking, without damage or restrike, fault currents nominated by Energex in this Schedule; and 4.1.3 new equipment including circuit-breakers provided to isolate the Customer’s facilities f ...
Ignition Hazards Caused by Electrostatic Charges in Industrial
Ignition Hazards Caused by Electrostatic Charges in Industrial

... poorly conducting surfaces. Examples in the broadest sense are the flow or filtration of non-conducting liquids, the movement of bulk solids in grinding, mixing or sifting operations, the pneumatic conveying of bulk solids, persons walking or vehicles running over insulating flooring materials, and ...
Collection versus Prevention
Collection versus Prevention

... strike point in that they are an efficient streamer generator. Thus they collect strikes and convey the energy to the ground rather than to the building or structure that it is protecting. Lightning rods have been used for more than 200 years, mounted to the tops of buildings and electrically bonded ...
Radio-Frequency Semiconductors Diodes
Radio-Frequency Semiconductors Diodes

... include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc. Unintended Usage of Toshiba products listed in this document shall be made at t ...
Comparing Performance of Current Ramp and Voltage Ramp Hot Swap Controller ICs
Comparing Performance of Current Ramp and Voltage Ramp Hot Swap Controller ICs

... interrupting power to the host. This feature is generally designed in wherever a need exists to replace modules on the fly. Such a requirement may be for purposes of repair, reconfiguration, redundancy, or system upgrade. Hot swap is useful in systems with high availability requirements such as PCI, ...
< 1 ... 31 32 33 34 35 36 37 38 39 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report