• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ECE 310 - Course Website Directory
ECE 310 - Course Website Directory

... Note: Connection introduces a 30 degree phase shift! Common for transmission/distribution step-down since there is a neutral on the low voltage side. Even if a = 1 there is a sqrt(3) step-up ratio ...
Chapter07
Chapter07

... 7-1: Series Voltage Dividers 7-2: Current Dividers with Two Parallel Resistances 7-3: Current Division by Parallel Conductances 7-4: Series Voltage Divider with Parallel Load Current 7-5: Design of a Loaded Voltage Divider © 2007 The McGraw-Hill Companies, Inc. All rights reserved. ...
2.4.1 RMS Word Document | GCE AS/A
2.4.1 RMS Word Document | GCE AS/A

Wide VIN power management ICs simplify White
Wide VIN power management ICs simplify White

... TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide adequate design and operating safeguar ...
SHORT CIRCUIT ANALYSIS FOR POWER SYSTEM NETWORKS
SHORT CIRCUIT ANALYSIS FOR POWER SYSTEM NETWORKS

... The process of evaluating the system voltages and currents under various types of short circuits is called fault analysis which can determine the necessary safety measures & the required protection system [2]. It is essential to guarantee the safety of public [3]. The analysis of faults leads to app ...
Electrical excitation of the local earth for resonant, wireless energy
Electrical excitation of the local earth for resonant, wireless energy

... the earth, the passive amplification allows a unique singlecontact mapping of F(r ) around the surface electrode, which hitherto has never been documented to our knowledge. Each receiver was calibrated such that their output standing-wave E-field would correspond to a known bottom terminal input volt ...
check for excessive current draw - Ask-A-Tech
check for excessive current draw - Ask-A-Tech

... 5. While monitoring the amperage reading on the multimeter, begin to remove fuses (one at a time) from each fuse location on the vehicle and see if the amperage drops. ...
Voltage Dividers and Current Dividers
Voltage Dividers and Current Dividers

... 7-1: Series Voltage Dividers  VT is divided into IR voltage drops that are proportional to the series resistance values.  Each resistance provides an IR voltage drop equal to its proportional part of the applied voltage: VR = (R/RT) × VT  This formula can be used for any number of series resista ...
STD830CP40
STD830CP40

... 29-Jun-2010 ...
Manual - CNCRoom
Manual - CNCRoom

... Take static discharge precautions; ground yourself by wearing a grounding strap or touching the metal chassis of earthed computer before touching electronic components. Hazardous voltages and current levels may exist on the MachDrive board. Disconnect all power cables to the MachDrive before touchin ...
ZXCL SERIES Micropower SC70-5 & SOT23-5 low dropout regulators
ZXCL SERIES Micropower SC70-5 & SOT23-5 low dropout regulators

... the user’s application and meets with the user’s requirements. No representation or warranty is given and no liability whatsoever is assumed by Zetex with respect to the accuracy or use of such information, or infringement of patents or other intellectual property rights arising from such use or oth ...
Solid-State Circuit Breakers and Current Limiters for
Solid-State Circuit Breakers and Current Limiters for

... losses are essential. As a result, the IGBT has a disadvantage in circuit breaker applications. Especially, the on-state losses of IGBTs are significantly higher than the losses of a thyristor based semiconductor (up to three times higher per device) [4], [5]. However, the IGBT has the advantage tha ...
ReliaGear ND Descriptive Bulletin
ReliaGear ND Descriptive Bulletin

... interlocking. Separate hard-wiring is not needed for the horizontal communication between the switchgear cubicles. Relion relays for feeder protection offer an optional cable fault detection function that can detect extremely short duration underground faults. These faults are typically undetectable ...
Sepam series 40 specification form
Sepam series 40 specification form

Electrical Machines lab –II Manual
Electrical Machines lab –II Manual

Multi Threshold Technique for High Speed and Low Power
Multi Threshold Technique for High Speed and Low Power

...  Created virtual VDD and ground rails  Distributed power gating  Simple to implement  High area overhead  Stack effect can degrade the performance  More immune to ground bounce or voltage droop  Sleep control signal for maintaining and storing the circuit state ...
Understanding of IC555 Timer and IC 555 Timer Tester
Understanding of IC555 Timer and IC 555 Timer Tester

... The IC was designed in 1971 by Hans Camenzind under contract to Signetics, which was later acquired by Philips (now NXP). Depending on the manufacturer, the standard 555 package includes 25 transistors, 2 diodes and 15 resistors on a silicon chip installed in an 8-pin mini dualin-line package (DIP-8 ...
Labf2002_4
Labf2002_4

... V implies a smaller current I for the same transmitted power. Smaller currents allow for the use of smaller wires with less loss. The high voltages used for power transmission, however, must be reduced to be compatible with the needs of most consumer and industrial electric equipment. This is done w ...
STS11NF30L
STS11NF30L

... Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ...
Datenblatt LEC.indd - ebm-os
Datenblatt LEC.indd - ebm-os

... Re-ignition is used in installation with multi-zone lighting. The LEC automatically switches to ignition mode when an increase of current is detected in one of the zones. ...
P20Z TYPE
P20Z TYPE

... Before switching the transducer on, one must check the correctness of connection to the network. Do not connect the transducer to the network through an autotransformer. Before removing the transducer housing, one must switch the supply off and disconnect measuring circuits. The removal of the meter ...
PDF - International Journal of Recent Scientific Research
PDF - International Journal of Recent Scientific Research

... fault in the particular location in the transmission line made to transmit to the nearest substation. There by the power through that transmission line is shutdown and is made retransmit through the secondary transmission line. In doing this the accidents can be avoided caused due to the High Impeda ...
HMC431LP4 数据资料DataSheet下载
HMC431LP4 数据资料DataSheet下载

... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
IOSR Journal of Electrical and Electronics Engineering PP 51-57 www.iosrjournals.org
IOSR Journal of Electrical and Electronics Engineering PP 51-57 www.iosrjournals.org

... economic losses. In order to solve the problems, faults automatic detection, location and isolation must be employed. Most faults can cause large currents or voltages changing, and they are often detected by traditional protective relay. Whereas, some faults, such as high impedance faults, grounding ...
Installing Grounding Lug Kits on Cisco 4000 Series Routers
Installing Grounding Lug Kits on Cisco 4000 Series Routers

... AccessPath, AtmDirector, the CCIE logo, CD-PAC, Centri, Centri Bronze, Centri Gold, Centri Security Manager, Centri Silver, the Cisco Capital logo, Cisco IOS, the Cisco IOS logo, CiscoLink, the Cisco NetWorks logo, the Cisco Powered Network logo, the Cisco Press logo, ClickStart, ControlStream, Fast ...
< 1 ... 280 281 282 283 284 285 286 287 288 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report