• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
TPS54372 数据资料 dataSheet 下载
TPS54372 数据资料 dataSheet 下载

... injected between the two grounds can degrade the performance of the TPS54372, particularly at higher output currents. Ground noise on an analog ground plane can also cause problems with some of the control and bias signals. For these reasons, separate analog and power ground traces are recommended. ...
W‑ST Wall‑mount Multi‑candela Strobes
W‑ST Wall‑mount Multi‑candela Strobes

Q. What is an arcing fault? A. An arcing fault is the
Q. What is an arcing fault? A. An arcing fault is the

... delays, open or shunted current transformers, open coils or dirty contacts. All of these factors could cause the results of flash hazard analysis to be inaccurate—causing the flash protection boundary to potentially be inaccurate. This could also affect the recommendations for the proper PPE. For th ...
2012S
2012S

Zener Diode Voltage Regulators
Zener Diode Voltage Regulators

... The purpose of a voltage regulator is to maintain a constant voltage across a load regardless of variations in the applied input voltage and variations in the load current. A typical Zener diode shunt regulator is shown in Figure 2. The resistor is sized so that when the input voltage is at VINmin a ...
14PE3 Coupled Inductor Based Current
14PE3 Coupled Inductor Based Current

... the traditional VSI, the proposed inverter does not need dead time circuit for its switching signals as it utilizes shoot-through state of the inverter in its single-stage configuration. Insertion of shoot-through state also helps it to achieve high boost operation essential for renewable energy app ...
steady and pulsed direct current welding with a single three
steady and pulsed direct current welding with a single three

MINIORE Hardware Description - Ottawa Robotics Enthusiasts
MINIORE Hardware Description - Ottawa Robotics Enthusiasts

... that may be generated either by the motor or other noisy devices (servos for instance). If the robot has a single power supply, it should be connected to both terminals (VPIC and VMOT). In practice, this will work the majority of the time anyhow (and is actually how I’m running it on my MiniORE sumo ...
Investigation of Polarization and Depolarization Current for
Investigation of Polarization and Depolarization Current for

... Abstract—The Polarization and Depolarization Current (PDC) analysis is a nondestructive dielectric testing method for determining the conductivity and moisture content of insulation materials in a transformer. The predominant influence of oil conductivity on the initial amplitudes of polarization/de ...
Chapter 8
Chapter 8

... – some devices allow voltages up to 30 V or more – others, designed for low voltages, may use 1.5 V – many op-amps permit single voltage supply operation, typically in the range 4 to 30 V Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 ...
P3.4.5.1 - LD Didactic
P3.4.5.1 - LD Didactic

... In this experiment the transformer is used to isolate two AC circuits electrically. There is no conductive connection between the primary and the secondary coils; both coils are coupled by the magnetic field. Therefore an earth free voltage source is available on the secondary side whose outputs can ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... actual voltage with voltage command and lower switch voltage method [5], where the measurement of the voltages is used, show a fast diagnosis performance and thus reduce the time between the fault occurrence and diagnosis. But its major drawback is to increase system cost as it requires extra hardwa ...
Numerical Arc Model Parameter Extraction for SF6 Circuit
Numerical Arc Model Parameter Extraction for SF6 Circuit

... 1998. He does research in the area of Power system transients, alternative energy sources, current interruption, circuit breaker modeling and design, plasma dynamics in vacuum and gases. ...
C Series C650 650 W Five Module Multi
C Series C650 650 W Five Module Multi

... improvements in the performance, reliability, or manufacturability of its products. Therefore, the user is cautioned to verify that the information in this publication is current before placing any order. When using the products described herein, the applicability and suitability of such products fo ...
Crane Safety Preventing Electrocutions From Contact With
Crane Safety Preventing Electrocutions From Contact With

... to apply swing limitation devices for use with mobile cranes, technology may be developed allowing them to be used in such cranes. Insulating Links Insulating links do not protect against encroachment but provide protection to employees handling the load against electrocution in the event that encro ...
Rajasthan Technical University Kota
Rajasthan Technical University Kota

... Write a program to calculate the power function (m") using the function overloading technique; implement it for power of integer and double. Implement file creation and operate it in different modes: seek, tell, read, write and close operations. Using multiple inheritance, prepare students' mark she ...
Electrical Safety Tester Verification
Electrical Safety Tester Verification

... Dielectric Withstand Test The Dielectric Withstand Test, commonly referred to as the high potential or “Hipot” test is an electrical safety test designed to stress the insulation of a device beyond what it would encounter during normal use. The logic behind running such a test is that if the device ...
HV Concepts HVCEB E-Beam 4kW to 6kW with single HV On
HV Concepts HVCEB E-Beam 4kW to 6kW with single HV On

... current levels set by the front panel potentiometers or the remote interface set points when under remote control. The preset level can be viewed at any time even while High Voltage is On as well as local or remote mode and is 5% accurate. Voltage LED: This LED located over the voltmeter, will light ...


R225-10-1
R225-10-1

... total circuit would be slightly higher than they appear to be at the regulator. One method of approximating this is to add a small value, probably less than 1%, to the total of the calculated transformer and secondary voltagedrop values. Another approach is suggested by the fact that the capacitors ...
PDF
PDF

... mostup-to-date technique to address the energy problems.Photovoltaic (PV) power generation systems are receivedmore and more attention in recent years. Due tothe large-scale manufacturing capability of the PV module, itis becoming increasingly cheaper during these last years. Sothe attempt to decrea ...
Fluke 1750 Three-Phase Power Recorder
Fluke 1750 Three-Phase Power Recorder

... applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more uncertainty that data is being recorded. The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the ...
Basic Schematic Interpretation
Basic Schematic Interpretation

... There are literally hundreds of different types of electrical and electronic components in use today. However, three components are widely used in a wide variety of applications. These three components are found in most circuit schematics of any complexity. The three components are (a) resistors; (b ...
Electrical Installation Kits
Electrical Installation Kits

... must have practical assignments to complete the course of study. The following list of training kits which are designed to meet with syllabus requirements and to eliminate wastage of planning and issue time. Each kit is complete with cables, screws and accessories required for the exercise. These ar ...
Protection of Control Circuit Transformers for applications in North
Protection of Control Circuit Transformers for applications in North

< 1 ... 242 243 244 245 246 247 248 249 250 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report