• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Fig.1. Schematic of the circuit model designed to simulate PV system
Fig.1. Schematic of the circuit model designed to simulate PV system

... KW to large installations of 0.1 MW. These PV systems can operate as stand-alone units supplying power to the residential loads. If the power generated is in excess, then it can be fed back to the AC grid. Due to the use of an inverter, the PV system draws nonlinear current thus resulting in distort ...
UCC2837 数据资料 dataSheet 下载
UCC2837 数据资料 dataSheet 下载

... The transient performance of a linear regulator built using the UCC3837 can be predicted by understanding the dynamics of the transient event. Consider a load transient on the application circuit of Fig. 1, where the output current steps from a low value to a high value. Initially, the output voltag ...
CAT32 - CMOS White LED Driver
CAT32 - CMOS White LED Driver

... copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation o ...
Project report
Project report

... The low threshold voltage transistors are power gated, i.e., they are stacked in series with high threshold voltage devices, called gating transistors that connects them to the power supply and the ground. The gating transistors are turned on during the active mode and are turned off during the slee ...
Electrical Safety - St. Olaf College
Electrical Safety - St. Olaf College

... Temporary electrical power and lighting installations 600 volts or less, including flexible cords, cables and extension cords, may only be used during and for renovation, maintenance, repair or experimental work. Temporary wiring may also be used for decorative lighting for special events and simila ...
A discriminating metal detector
A discriminating metal detector

... As the general principles of operation have been discussed with regard to the block diagram in the text, this description is confined to the Circuit alone. Commencing with the transmitter, Q3 is configured as a Colpitts Oscillator, the transmit coil in the search head forming the inductance which re ...
Distribution High Impedance Fault Location Using Localized Voltage
Distribution High Impedance Fault Location Using Localized Voltage

... ground or when the conductor comes in contact with quasiinsulating objects such as trees, poles, or other equipment. These types of faults are difficult to detect using conventional protective devices that are triggered by overcurrents. Although the low currents cause little damage to network compone ...
POWERFIELDS www.powerfields.com FENCE
POWERFIELDS www.powerfields.com FENCE

... fence load. Green plants draw voltage and amperage from the fence to the earth. Other circumstances can rob the fence of voltage and amperage. Cracked or broken insulators, or insulators of poor design will allow electricity to leak to the fence post and return to earth. Sagging or broken wires can ...
History of System Lightning Requirements
History of System Lightning Requirements

... controlled to be consistent with this level. The power associated with this level represents a threat to most electronic interface circuits and the impact on equipment practices will be significant. Additionally, the open circuit voltage associated with is within region where the withstand capabilit ...
FAN2001/FAN2002 1A High-Efficiency Step-Down DC-DC Converter F
FAN2001/FAN2002 1A High-Efficiency Step-Down DC-DC Converter F

... 1. Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposu ...
section 16340-1 - Schneider Electric
section 16340-1 - Schneider Electric

... 1. The circuit breakers shall be rated [ ] nominal volts, [4760] [8250] [15000] maximum volts, 60 Hz, with a continuous current rating of [1200] [2000] [3000] amps and a maximum symmetrical interrupting rating* of [40kA/250mVA - 4.76 kV system] [50kA/350MVA - 4.76 kV system] [63kA/500MVA - 4.76 kV s ...
SECTION 260553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS
SECTION 260553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS

High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers

Glossary of technical terms
Glossary of technical terms

... in the atmosphere is fixed (ie, converted into solid matter) by the process of photosynthesis in plants and green algae. These then die and rot under the influence of bacteria and fungi or are consumed by higher organisms in the form of food or fuel (burning plant matter or fossil fuels). Either way ...
A high-voltage bipolar voltage-to-current converter (HVB-VIC)
A high-voltage bipolar voltage-to-current converter (HVB-VIC)

... bipolar pulses. Achieving higher potentials (±400 V bipolar, reconfigurable for higher potential asymmetric pulses) requires a bridge configuration, necessitating either floating the load or the entire amplifier circuit. The former option is not desirable for safety and performance reasons. If coaxi ...
Faculty of Engineering - Pharos University in Alexandria
Faculty of Engineering - Pharos University in Alexandria

555timer - EngineeringDuniya.com
555timer - EngineeringDuniya.com

EMC: electromagnetic compatibility
EMC: electromagnetic compatibility

... currents of several hundred milliamperes. This disturbance current will flow through the zero reference conductor and can modify signals (data or commands), be superimposed on sensitive measurements and disturb other equipment by injecting the disturbance back into the public distribution network. O ...
IEEE-NFPA Small Wire Report
IEEE-NFPA Small Wire Report

... conductors for branch circuits was divided into two major categories: verification of overload protection, and verification of short-circuit protection. Following each test, the conductor was visually inspected, then subjected to dielectric testing per UL83, section 27. A. Verification of Short-Circ ...
30104 Operate electrical switchgear in the electricity
30104 Operate electrical switchgear in the electricity

JI3516041608
JI3516041608

... this there is a need for the cooling process. So, there is a need for heat sinks and cooling fans for heat exhaust. The dual sub-threshold supply voltage technique would help to operate where complex devices need to consume less power. Thereby, the complex circuits will dissipate less amount of powe ...
Magnetic effect of current
Magnetic effect of current

MN280033EN
MN280033EN

... utilize an off-line switcher for the primary stage, generating a high-voltage bus, and a second stage switcher for the isolated control power feature of the automation power supply. The AC voltage monitor circuit is completely contained on the power supply board, along with the CPU interface drivers ...
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS)
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS)

... power quality problems occur when a nonstandard voltage, current or frequency results in failure or maloperation of end user equipments. The most important PQ issues are voltage sag [4, 5], and harmonics [6]. To reduce the severity of PQ problems, mitigation devices can be placed in the transmission ...
P2030 Smart Grid Standard Text Submittal Form This text is
P2030 Smart Grid Standard Text Submittal Form This text is

... ∙ Near real-time - Updates once every five to fifteen minutes or more frequently as required by operator or computer system (e.g. DMS or EMS), with provision for on-demand update. ...
< 1 ... 225 226 227 228 229 230 231 232 233 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report