• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
chapter 5
chapter 5

... There is no piece of electrical equipment that does not depend on electrical insulation in one form or other to maintain the flow of electric current in desired paths or circuits. If due to some reason the current deviates from the desired path, the potential will drop. An example of this is a short ...
Selective Coordination Overview of Short Circuit Selective
Selective Coordination Overview of Short Circuit Selective

... occurs. 6.5.2 Short Circuit Current. The maximum available short circuit current from both the utility source and the emergency energy source shall be evaluated for the ability to satisfy this coordination capability. ...
GZ2512721277
GZ2512721277

... ZVS operation can only be achieved with a limited load and input-voltage range, unless a relatively large inductance is provided in series with the primary winding of the transformer either by an increased leakage inductance of the transformer and/or by an additional external inductor. This increase ...
Chapter 13 — Permitting and Inspection
Chapter 13 — Permitting and Inspection

... drawings of the array mounting design and materials are used to analyze the structural integrity of the structure and the array. ...
Electricity - School
Electricity - School

... State which fuse to install in an appliance based on normal working current State the danger of installing a fuse of too high a rating Explain how an earth wire protects the user from getting an electric shock if a fault occurs Explain why some devices don’t require an earth wire State UK mains freq ...
DRV8870 3.6-A Brushed DC Motor Driver (PWM
DRV8870 3.6-A Brushed DC Motor Driver (PWM

... inputs control the H-bridge driver, which consists of four N-channel MOSFETs that have a typical Rds(on) of 565 mΩ (including one high-side and one low-side FET). A single-power input, VM, serves as both device power and the motor winding bias voltage. The integrated charge pump of the device boosts ...
Trame Rapport
Trame Rapport

... Electrical characteristics ...
Transformer Fundamental
Transformer Fundamental

... • Voltage Transformer VT (or PT) – N1/N2 is large and standard 110 V at the secondary. • Current Transformer CT – N1/N2 is small and standard 5 A or 1A at the secondary. • Reduce the voltage or current magnitudes so that instruments can be used. • Instruments are connected to the secondary of the tr ...
Guide for Electric Service and Meter Installations
Guide for Electric Service and Meter Installations

Linn Klimax 500 Twin Power Amplifier
Linn Klimax 500 Twin Power Amplifier

... Power sources. Connect the appliance to a power supply only of the type described in the operating instructions or marked on the appliance. Grounding or polarisation. Do not defeat the safety purpose of the polarised or grounding type plug. A polarised plug has two blades with one wider than the oth ...
976-Support for Non-Specialists Teaching Physics ( Electricity )
976-Support for Non-Specialists Teaching Physics ( Electricity )

Roll-ur-Own Crowbar OV Module.
Roll-ur-Own Crowbar OV Module.

... in the assembly instructions. If Q3 is wired correctly, try reducing the value of R4 to 10 ohms (reduced from 51.1 ohms in earlier versions). Other Potential Difficulties: The occasional crowbar OV protection module will be sensitive to radio transmissions. This difficulty is most often caused by “l ...
General
General

... From here the mains supply is split into various domestic c _i _ r_ c_ u_ i t_ s_ . The lights, power sockets and cooker e_ p_ a_ r_ a_ t_ e circuits which are wired in each have s _ a _r _ a_ l l_e_l_ . p_ The parallel wiring ensures each circuit has the same 230 V voltage needed to operate applian ...
FSQ0465RS/RB Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -
FSQ0465RS/RB Green-Mode Fairchild Power Switch (FPS™) for Quasi-Resonant Operation -

... noise and loss. The basic waveforms of the quasiresonant converter are shown in Figure 25. To minimize the MOSFET's switching loss, the MOSFET should be turned on when the drain voltage reaches its minimum value, which is indirectly detected by monitoring the VCC winding voltage, as shown in Figure ...
Active Harmonic Filtering Solutions Catalogue
Active Harmonic Filtering Solutions Catalogue

Basic Electrical Engineering for HVAC Engineers
Basic Electrical Engineering for HVAC Engineers

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... causing uncontrollable excessive rotor over-currents. These currents can damage the power electronic devices of the power converter. Also, the electromagnetic torque of the DFIG starts to oscillate with high amplitudes causing mechanical stresses to the wind turbine system [9]. Initially, the soluti ...
MIC33163/4 General Description Features 4MHz, 1A, Buck Regulator with Integrated
MIC33163/4 General Description Features 4MHz, 1A, Buck Regulator with Integrated

... power ground should be as small as possible and separate from the analog ground (AGND) loop as applicable. Refer to the PCB Layout Recommendations section for details. PG The power good (PG) pin is an open drain output which indicates logic high when the output voltage is typically above 90% of its ...
vc 400-045 vectron elektronik manual
vc 400-045 vectron elektronik manual

... The frequency inverters are integrated in a drive system consisting of a number of components. The electromagnetic compatibility (EMC) only has to be assessed for the overall system. This is why compliance with the EMC Guideline and EMC Law can only be achieved through the EMC-compatible design as s ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... conditions. The parameters of the lead-lag compensator are adjusted so that the phase shift between the speed deviation and the resulting electrical torque at the desired frequency is compensated. In the following, an additional electrical damping torque output is acquired in phase with the speed de ...
PRACTICAL ASSESSMENT
PRACTICAL ASSESSMENT

Customer Service Standards for Connection
Customer Service Standards for Connection

... Customers should notify Endeavour Energy of their supply requirements so that appropriated arrangements can be made. This particularly applies where a customer intends to install items of equipment which: • Place large electrical loads on the electrical distribution system; or • May affect the quali ...
Class notes on Thevenin Equivalent Circuits
Class notes on Thevenin Equivalent Circuits

... is replaced by a short. • When a resistor connects to nothing, there will be no current through it and, thus, no voltage across it. ...
CENTRAL STAFF TRAINING AND RESEARCH INSTITUTE  MINISTRY OF LABOUR AND EMPLOYMENT
CENTRAL STAFF TRAINING AND RESEARCH INSTITUTE MINISTRY OF LABOUR AND EMPLOYMENT

High-voltage switch using series-connected
High-voltage switch using series-connected

... The series operation of self turn-off devices is not easy because of the following reasons: • unequal device switching characteristics; • unequal device leakage current; • unequal stray inductance in the series circuit; • unequal gate drive delay. Fig. 2 shows the typical waveforms of two series-con ...
< 1 ... 188 189 190 191 192 193 194 195 196 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.