thyristors and triacs control gate trigger circuits
... using specialized integrated circuits (eg. UAA145). The trigger control circuits manufacturing without dedicated integrated circuits can be justified today only for simple applications, such as the structures with a single low power thyristor or triac. Choosing a trigger control circuit with discret ...
... using specialized integrated circuits (eg. UAA145). The trigger control circuits manufacturing without dedicated integrated circuits can be justified today only for simple applications, such as the structures with a single low power thyristor or triac. Choosing a trigger control circuit with discret ...
Coaxial Transmitting Chokes
... • Field mostly between the two conductors • No distant radiation from ideal line – At great distance, field of one conductor cancels field of the other conductor ...
... • Field mostly between the two conductors • No distant radiation from ideal line – At great distance, field of one conductor cancels field of the other conductor ...
Annex I High Voltage - Loughborough University
... who the permit is issued to & defining the scope & limitations of the work. •. SAFETY LOCK – a lock that has a unique key, being different from all other standard locks used on the system. • SCREENED - barriered off to prevent contact with LIVE conductors. • SWITCHING – the operation of circuit brea ...
... who the permit is issued to & defining the scope & limitations of the work. •. SAFETY LOCK – a lock that has a unique key, being different from all other standard locks used on the system. • SCREENED - barriered off to prevent contact with LIVE conductors. • SWITCHING – the operation of circuit brea ...
1.5 A 280 kHz/560 kHz Boost Regulators
... and reduce the supply current. An additional feature includes frequency shift to 20% of the nominal frequency when either the NFB or FB pins trigger the threshold. During power up, overload, or short circuit conditions, the minimum switch on−time is limited by the PWM comparator minimum pulse width. ...
... and reduce the supply current. An additional feature includes frequency shift to 20% of the nominal frequency when either the NFB or FB pins trigger the threshold. During power up, overload, or short circuit conditions, the minimum switch on−time is limited by the PWM comparator minimum pulse width. ...
PowerPoint 簡報
... of at least 2m x 2m,and shall be dept at least 0.8m from any other metal surface or other ground plane not being part of the EUT.If the measurement is made in a screened enclosure, the distance of 0.4m may be referred to one of the walls of the enclosure.If the measurement is made in an open area te ...
... of at least 2m x 2m,and shall be dept at least 0.8m from any other metal surface or other ground plane not being part of the EUT.If the measurement is made in a screened enclosure, the distance of 0.4m may be referred to one of the walls of the enclosure.If the measurement is made in an open area te ...
Circuit Note
... The USB interface to the ADuCM360/ADuCM361 is implemented with an FT232R UART to USB transceiver, which converts USB signals directly to the UART. In addition to the decoupling shown Figure 1, the USB cable itself must have a ferrite bead for added EMI/RFI protection. The ferrite beads used in the c ...
... The USB interface to the ADuCM360/ADuCM361 is implemented with an FT232R UART to USB transceiver, which converts USB signals directly to the UART. In addition to the decoupling shown Figure 1, the USB cable itself must have a ferrite bead for added EMI/RFI protection. The ferrite beads used in the c ...
transformer regulated brushless generator
... to verify upon installation. To supply 60 HZ, the speed should be 1800 to 1860 RPM at no load and should not fall below 1800 RPM by more than one percent at full load. To supply 50 HZ, the speed should be 1500 to 1550 RPM at no load and 1500 RPM at full load. The generator voltage should build to it ...
... to verify upon installation. To supply 60 HZ, the speed should be 1800 to 1860 RPM at no load and should not fall below 1800 RPM by more than one percent at full load. To supply 50 HZ, the speed should be 1500 to 1550 RPM at no load and 1500 RPM at full load. The generator voltage should build to it ...
BD8271EFV
... ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. ...
... ground will not cause the IC and the system to malfunction by examining carefully all relevant factors and conditions such as motor characteristics, supply voltage, operating frequency and PCB wiring to name a few. ...
Guide to Electrical Safety Testing
... Hipot test time (dwell time) can also vary between agency standards. The most common test durations are 1 sec for production tests and 1 minute for design tests. However, if the test time is reduced from 1 min to 1 sec, the Hipot test voltage generally needs to be raised by 20% since the insulation ...
... Hipot test time (dwell time) can also vary between agency standards. The most common test durations are 1 sec for production tests and 1 minute for design tests. However, if the test time is reduced from 1 min to 1 sec, the Hipot test voltage generally needs to be raised by 20% since the insulation ...
AN-847 APPLICATION NOTE
... AD5933 and AD8220 have a high PSRR specification. However, for optimum performance, a stable dc voltage should be used to power both chips because noise on the supply lines can adversely affect circuit performance. The power supply to both parts is decoupled using standard surface-mount, 0.1 μF cera ...
... AD5933 and AD8220 have a high PSRR specification. However, for optimum performance, a stable dc voltage should be used to power both chips because noise on the supply lines can adversely affect circuit performance. The power supply to both parts is decoupled using standard surface-mount, 0.1 μF cera ...
HIS – Highly Integrated Switchgear up to 550 kV, 63 kA
... voltage. The high-voltage connection to the switchgear is established via the primary conductor, which is supported by a gastight bushing. The secondary connections are routed via a gastight bushing plate to the terminal box. Resistive-capacitive voltage dividers (RCVD) consist of oilimpregnated cap ...
... voltage. The high-voltage connection to the switchgear is established via the primary conductor, which is supported by a gastight bushing. The secondary connections are routed via a gastight bushing plate to the terminal box. Resistive-capacitive voltage dividers (RCVD) consist of oilimpregnated cap ...
LMG3410 600-V 12-A Single Channel GaN
... Server/Telecom AC-DC Supplies Rack-Mount Server DC Power Distribution Solar Inverters Motor Drives ...
... Server/Telecom AC-DC Supplies Rack-Mount Server DC Power Distribution Solar Inverters Motor Drives ...
BD555A1AFV
... 4) AUX Low Voltage Detection When AUX power supply voltage is low or any abnormal problem occurs such as AUX pin short, IC is turned non-active, since there is a possibility that IC does not operate properly. In non-active mode, switching operation stops. Gate driver output turns into low impedance ...
... 4) AUX Low Voltage Detection When AUX power supply voltage is low or any abnormal problem occurs such as AUX pin short, IC is turned non-active, since there is a possibility that IC does not operate properly. In non-active mode, switching operation stops. Gate driver output turns into low impedance ...
Laser and Photonics Technician - Florida Department Of Education
... 01.12 Identify basic limitations of multimeters, oscilloscopes, function generators, and power supplies. 01.13 Use digital multi-meters (DMM), oscilloscopes, function generators, and power supplies to build, analyze and trouble shoot electrical/electronic circuits. ...
... 01.12 Identify basic limitations of multimeters, oscilloscopes, function generators, and power supplies. 01.13 Use digital multi-meters (DMM), oscilloscopes, function generators, and power supplies to build, analyze and trouble shoot electrical/electronic circuits. ...
Optocoupler, Phototriac Output, Zero Crossing, High dV/dt, Low
... of greater than 10 kV/ms. This clamp circuit has a MOSFET that is enhanced when high dV/dt spikes occur between MT1 and MT2 of the TRIAC. When conducting, the FET clamps the base of the phototransistor, disabling the first stage SCR predriver. The zero cross line voltage detection circuit consists o ...
... of greater than 10 kV/ms. This clamp circuit has a MOSFET that is enhanced when high dV/dt spikes occur between MT1 and MT2 of the TRIAC. When conducting, the FET clamps the base of the phototransistor, disabling the first stage SCR predriver. The zero cross line voltage detection circuit consists o ...
Lab Manual - Lakehead University
... that use, i.e. grid, proper scaling and correct labelling can be achieved and the plot is smooth. If a graph is used to extract data or to provide some precise information, show precisely how the information is obtained (here it may be better to draw it on graph paper by hand - usually is faster, to ...
... that use, i.e. grid, proper scaling and correct labelling can be achieved and the plot is smooth. If a graph is used to extract data or to provide some precise information, show precisely how the information is obtained (here it may be better to draw it on graph paper by hand - usually is faster, to ...
Current transformer selection guide
... In the somewhat infrequent case in which it is not possible to use a calibration CT (as the accuracy power is too high), the rated current depends on the transformer coupling. Determination of the calibrating CTs will be studied subsequently in binder C. ...
... In the somewhat infrequent case in which it is not possible to use a calibration CT (as the accuracy power is too high), the rated current depends on the transformer coupling. Determination of the calibrating CTs will be studied subsequently in binder C. ...
Basic Facts about Electrical Safety Testing
... to another, one side of the secondary is grounded. In household power distribution all neutral wires in a house are connected to ground at a single point. Some power is distributed ungrounded so that the system will tolerate one fault to ground without shutting down. This typically is high voltage i ...
... to another, one side of the secondary is grounded. In household power distribution all neutral wires in a house are connected to ground at a single point. Some power is distributed ungrounded so that the system will tolerate one fault to ground without shutting down. This typically is high voltage i ...
AVR493 - Atmel Corporation
... Another possibility is to control the PWM duty cycle open loop as a function of the actual velocity during acceleration. This open loop regulation can be done based on the known parameters of the BLDC motor. The open loop speed up has been realized (refer to Figure 2.5). The goal of open loop ramp u ...
... Another possibility is to control the PWM duty cycle open loop as a function of the actual velocity during acceleration. This open loop regulation can be done based on the known parameters of the BLDC motor. The open loop speed up has been realized (refer to Figure 2.5). The goal of open loop ramp u ...
HEWITT PYROMETERS Installation Instructions
... NOTES: Tight clean wire connections to thermocouple are critical. Heat shrink tubing on thermocouple supplied for insulation after connections are made. DO NOT connect tester leads to voltage, damage will occur! Once calibrated, pyrometer calibration does not change. Page 2 of 2 ...
... NOTES: Tight clean wire connections to thermocouple are critical. Heat shrink tubing on thermocouple supplied for insulation after connections are made. DO NOT connect tester leads to voltage, damage will occur! Once calibrated, pyrometer calibration does not change. Page 2 of 2 ...
ET 36 Answers
... This schedule sets out the accepted answers to the examination questions. A marker can exercise their discretion and decide on the overall accuracy of any answer that is presented in the candidate’s own words. ...
... This schedule sets out the accepted answers to the examination questions. A marker can exercise their discretion and decide on the overall accuracy of any answer that is presented in the candidate’s own words. ...
Ground (electricity)
In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.