
IS31AP2145A - Integrated Silicon Solution Inc.
... the audio signal by which we can enhance audio quality and also protect the speaker from damage at high power levels. The AGC function and its attack time/release time are selectable via the CTRL pin. The IS31AP2145A also provides thermal and over current protection functions. In addition to these f ...
... the audio signal by which we can enhance audio quality and also protect the speaker from damage at high power levels. The AGC function and its attack time/release time are selectable via the CTRL pin. The IS31AP2145A also provides thermal and over current protection functions. In addition to these f ...
Inductively coupled power transfer (ICPT) for electric
... wires [14]. However the EVs are operated by means of electrical energy, so these are polluting the environment indirectly depending on the source of energy. They operate with low emissions of greenhouse gases [15]. Furthermore, they can be used with smart house systems to supplement the energy stora ...
... wires [14]. However the EVs are operated by means of electrical energy, so these are polluting the environment indirectly depending on the source of energy. They operate with low emissions of greenhouse gases [15]. Furthermore, they can be used with smart house systems to supplement the energy stora ...
AN-750 APPLICATION NOTE
... register has elapsed. However, as mentioned previously, noise and offset on the voltage channel may cause the part to continue detecting zero crossing. Therefore, no ZXTOUT interrupt is generated. In this situation, SAG can be used to detect the phase dropout condition. If the SAG bits in the MASK r ...
... register has elapsed. However, as mentioned previously, noise and offset on the voltage channel may cause the part to continue detecting zero crossing. Therefore, no ZXTOUT interrupt is generated. In this situation, SAG can be used to detect the phase dropout condition. If the SAG bits in the MASK r ...
Aalborg Universitet A New Power Calculation Method for Single-Phase Grid-Connected Systems
... Abstract— A new method to calculate average active power and reactive power for single-phase systems is proposed in this paper. It can be used in different applications where the output active power and reactive power need to be calculated accurately and fast. For example, a grid-connected photovolt ...
... Abstract— A new method to calculate average active power and reactive power for single-phase systems is proposed in this paper. It can be used in different applications where the output active power and reactive power need to be calculated accurately and fast. For example, a grid-connected photovolt ...
section 15170-motors - DeCA Facilities Website
... with required motor leads. Provide terminals in motor terminal box, suited to control method. ...
... with required motor leads. Provide terminals in motor terminal box, suited to control method. ...
Low Power Designs with CoolRunner-II CPLDs
... toggles the internal logic of the CPLD. Any logic that changes state within the CPLD will consume power. Therefore, it follows that disconnecting the CPLD from the data bus when the device is not addressed conserves power. DataGATE solves this issue by disconnecting external signal activity from the ...
... toggles the internal logic of the CPLD. Any logic that changes state within the CPLD will consume power. Therefore, it follows that disconnecting the CPLD from the data bus when the device is not addressed conserves power. DataGATE solves this issue by disconnecting external signal activity from the ...
FAN6862H / FAN6862HR Highly Integrated Green-Mode PWM Controller
... General-purpose switched-mode power supplies and flyback power converters, including: ...
... General-purpose switched-mode power supplies and flyback power converters, including: ...
O A RIGINAL RTICLES
... Two main weaknesses of band-pass filters with spiral inductors and transformers are the low pass-band center frequency stem from the large spiral-substrate capacitance and the high insertion loss due to both the skin-effect induced parasitic resistance of the spiral and the substrate eddy-current in ...
... Two main weaknesses of band-pass filters with spiral inductors and transformers are the low pass-band center frequency stem from the large spiral-substrate capacitance and the high insertion loss due to both the skin-effect induced parasitic resistance of the spiral and the substrate eddy-current in ...
investigation of numerical technique to evaluate frequency response
... Now, one of the methods which are becoming an increasingly important condition monitoring tool is the Frequency Response Analysis (FRA) technique. This method involves measuring the transfer function of the transformer windings as a function of frequency. Any disruption of the winding arrangement wi ...
... Now, one of the methods which are becoming an increasingly important condition monitoring tool is the Frequency Response Analysis (FRA) technique. This method involves measuring the transfer function of the transformer windings as a function of frequency. Any disruption of the winding arrangement wi ...
FSFR2100 — Fairchild Power Switch (FPS™) for Half-Bridge Resonant Converters
... To prevent excessive inrush current and overshoot of output voltage during startup, increase the voltage gain of the resonant converter progressively. Since the voltage gain of the resonant converter is inversely proportional to the switching frequency, the soft-start is implemented by sweeping down ...
... To prevent excessive inrush current and overshoot of output voltage during startup, increase the voltage gain of the resonant converter progressively. Since the voltage gain of the resonant converter is inversely proportional to the switching frequency, the soft-start is implemented by sweeping down ...
MTech_in_electrical_Engineering
... Field Quality Tests on Power Cables, Control Cables, Principles of Control Cable Installation, The Sensitivity of Various Loads to interference , Definitions, Laying of Control Cables and Measuring Cables , Grounding of Cable Trays, Ducts, Electrical Noise, Protection of Static Relay Circuit and Con ...
... Field Quality Tests on Power Cables, Control Cables, Principles of Control Cable Installation, The Sensitivity of Various Loads to interference , Definitions, Laying of Control Cables and Measuring Cables , Grounding of Cable Trays, Ducts, Electrical Noise, Protection of Static Relay Circuit and Con ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.