
Full Report - Cornell ECE
... (roughly two octaves’ worth) at varying volumes (roughly 8-10 distinct volumes) will come out of the speaker at the output. Traditional Theremin: The Theremin is a musical instrument created by Lev Termen (also spelled Leon Theremin) in 1917, with two antennas—one vertical and one horizontal. It is ...
... (roughly two octaves’ worth) at varying volumes (roughly 8-10 distinct volumes) will come out of the speaker at the output. Traditional Theremin: The Theremin is a musical instrument created by Lev Termen (also spelled Leon Theremin) in 1917, with two antennas—one vertical and one horizontal. It is ...
Document
... These graphs strongly resemble those that one would expect to see in case of simple electrical circuit with direct current and constant resistance. Though, it is seen that the curves do not trend to zero, as it would be for a simple resistor. ...
... These graphs strongly resemble those that one would expect to see in case of simple electrical circuit with direct current and constant resistance. Though, it is seen that the curves do not trend to zero, as it would be for a simple resistor. ...
ADM660 数据手册DataSheet 下载
... The switched capacitor may, therefore, be replaced by an equivalent resistance whose value is dependent on both the capacitor size and the switching frequency. This explains why lower capacitor values may be used with higher switching frequencies. It should be remembered that as the switching freque ...
... The switched capacitor may, therefore, be replaced by an equivalent resistance whose value is dependent on both the capacitor size and the switching frequency. This explains why lower capacitor values may be used with higher switching frequencies. It should be remembered that as the switching freque ...
NCV887300LEDGEVB NCV887300 Automotive Grade High‐frequency Dimmable LED Boost
... limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for ea ...
... limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for ea ...
The Seven Types of Power Problems
... potential for ESD. For example, almost any proper data center environment involves conditioning of the air in the room. Conditioning the air does not just cool the air to help remove heat from data center equipment, but also adjusts the amount of moisture in the air. Keeping the humidity in the air ...
... potential for ESD. For example, almost any proper data center environment involves conditioning of the air in the room. Conditioning the air does not just cool the air to help remove heat from data center equipment, but also adjusts the amount of moisture in the air. Keeping the humidity in the air ...
Power Electronics Converters for Variable Speed Pump
... stator of the doubly fed machine is connected through a block transformer to the power network. The rotor is driven by an adjustable blade turbine and fed from a power electronics converter. Nowadays, the research of power electronics converters used in variable-speed pump storage is a multilevel in ...
... stator of the doubly fed machine is connected through a block transformer to the power network. The rotor is driven by an adjustable blade turbine and fed from a power electronics converter. Nowadays, the research of power electronics converters used in variable-speed pump storage is a multilevel in ...
AN020: Paralleling High Speed GaN Transistors
... As switching speeds steadily increase and parasitic inductances continue to decrease, improved techniques must be developed to improve parallel performance. To effectively parallel high speed GaN transistors the parasitic imbalance contributed by the PCB layout must be minimized. We will look at two ...
... As switching speeds steadily increase and parasitic inductances continue to decrease, improved techniques must be developed to improve parallel performance. To effectively parallel high speed GaN transistors the parasitic imbalance contributed by the PCB layout must be minimized. We will look at two ...
H4148
... Sliding-Mode Controllers are non-linear controllers which are used for controlling the variable structure systems (VSSs) [1]-[3]. The power converters are variable-structured systems due to their high switching action. Hence SM controllers are used for control of power converters [4]. The SM control ...
... Sliding-Mode Controllers are non-linear controllers which are used for controlling the variable structure systems (VSSs) [1]-[3]. The power converters are variable-structured systems due to their high switching action. Hence SM controllers are used for control of power converters [4]. The SM control ...
motors
... the direction of rotation of magnetic field by interchanging any two of the line connections. The speed of revolving of the magnetic field produced by primary currents is called the synchronous speed of the motor, and is given by N= 120f/p where f is the supply frequency and p is the number of poles ...
... the direction of rotation of magnetic field by interchanging any two of the line connections. The speed of revolving of the magnetic field produced by primary currents is called the synchronous speed of the motor, and is given by N= 120f/p where f is the supply frequency and p is the number of poles ...
Document
... Recognizing that G RIN << R1 for low gains, it can be seen to the first order that bandwidth for this amplifier is independent of gain (G). Considering that additional poles contribute excess phase at high frequencies, there is a minimum feedback resistance below which peaking or oscillation may r ...
... Recognizing that G RIN << R1 for low gains, it can be seen to the first order that bandwidth for this amplifier is independent of gain (G). Considering that additional poles contribute excess phase at high frequencies, there is a minimum feedback resistance below which peaking or oscillation may r ...
TQP4M9071 数据资料DataSheet下载
... The TQP4M9071 is a high linearity, low insertion loss, wideband, 6-bit, 31.5 dB digital step attenuator. The digital step attenuator uses a single 3.3V or 5V supply and has a parallel control interface for changing attenuation states. This product maintains high attenuation accuracy over frequency a ...
... The TQP4M9071 is a high linearity, low insertion loss, wideband, 6-bit, 31.5 dB digital step attenuator. The digital step attenuator uses a single 3.3V or 5V supply and has a parallel control interface for changing attenuation states. This product maintains high attenuation accuracy over frequency a ...
Broadband Communications over Power Lines (BPL)
... • HomePlug uses a spectral mask that provides 30 dB of filtering in the amateur HF bands. • At current RF brightness levels of –80 dBm/Hz, HomePlug signals can cause interference to antennas (especially indoor) that run within 2 – 3 m of household power lines. • HomePlug signals can also leak into ...
... • HomePlug uses a spectral mask that provides 30 dB of filtering in the amateur HF bands. • At current RF brightness levels of –80 dBm/Hz, HomePlug signals can cause interference to antennas (especially indoor) that run within 2 – 3 m of household power lines. • HomePlug signals can also leak into ...
DC microgrids (droop control)
... controlling the prime mover’s torque. By “commanding” a decrease in frequency, the output power will increase. • A similar approach is followed with reactive power control, by controlling field excitation in an attempt to change output voltage. Higher commanded frequencies ...
... controlling the prime mover’s torque. By “commanding” a decrease in frequency, the output power will increase. • A similar approach is followed with reactive power control, by controlling field excitation in an attempt to change output voltage. Higher commanded frequencies ...
Dynamic Study Model for the Interconnected Power - ENTSO-e
... underwent some adaptation steps, before it was distributed: • adding of step-up transformers for generators directly connected to the transmission level, • reduction of parallel lines, • reduction of coupled busbars, • aggregation of multiple loads at busbars and • aggregation of multiple generation ...
... underwent some adaptation steps, before it was distributed: • adding of step-up transformers for generators directly connected to the transmission level, • reduction of parallel lines, • reduction of coupled busbars, • aggregation of multiple loads at busbars and • aggregation of multiple generation ...
Dynamic Study Model for the Interconnected Power
... underwent some adaptation steps, before it was distributed: • adding of step-up transformers for generators directly connected to the transmission level, • reduction of parallel lines, • reduction of coupled busbars, • aggregation of multiple loads at busbars and • aggregation of multiple generation ...
... underwent some adaptation steps, before it was distributed: • adding of step-up transformers for generators directly connected to the transmission level, • reduction of parallel lines, • reduction of coupled busbars, • aggregation of multiple loads at busbars and • aggregation of multiple generation ...
Utility frequency
The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the frequency of the oscillations of alternating current (AC) in an electric power grid transmitted from a power plant to the end-user. In large parts of the world this is 50 Hz, although in the Americas and parts of Asia it is typically 60 Hz. Current usage by country or region is given in the list of mains power around the world.During the development of commercial electric power systems in the late 19th and early 20th centuries, many different frequencies (and voltages) had been used. Large investment in equipment at one frequency made standardization a slow process. However, as of the turn of the 21st century, places that now use the 50 Hz frequency tend to use 220–240 V, and those that now use 60 Hz tend to use 100–127 V. Both frequencies coexist today (Japan uses both) with no great technical reason to prefer one over the other and no apparent desire for complete worldwide standardization.Unless specified by the manufacturer to operate on both 50 and 60 Hz, appliances may not operate efficiently or even safely if used on anything other than the intended frequency.