Detector Selection for Spectrum analyzer Measurements
... spectrum analysis. FFT computation results are just samples of a continuous spectrum. Fig- ure B applies di- rectly to FFT an- alysis, except that the period of the scallop is one FFT bin in- stead of one bucket. Designers of FFT processing choose a “windowing” operation partly to control the scallo ...
... spectrum analysis. FFT computation results are just samples of a continuous spectrum. Fig- ure B applies di- rectly to FFT an- alysis, except that the period of the scallop is one FFT bin in- stead of one bucket. Designers of FFT processing choose a “windowing” operation partly to control the scallo ...
CANwatch - EMS Dr. Thomas Wünsche
... means that the number of error frames related to the number of registered and evaluated telegrams is 0.1 - 1%. The display is divided into the ranges 0.1 - 1%, 1 - 5%, 5 - 100%. ...
... means that the number of error frames related to the number of registered and evaluated telegrams is 0.1 - 1%. The display is divided into the ranges 0.1 - 1%, 1 - 5%, 5 - 100%. ...
Pi Speaker Alignment Theory
... dynamic range, efficiency and power handling aren’t measures of accuracy – they are very important indicators of the overall quality of a loudspeaker. Efficiency is rated in decibels – over our threshold of hearing – with one watt of electrical energy. Specifically, the amount of energy required for ...
... dynamic range, efficiency and power handling aren’t measures of accuracy – they are very important indicators of the overall quality of a loudspeaker. Efficiency is rated in decibels – over our threshold of hearing – with one watt of electrical energy. Specifically, the amount of energy required for ...
Photonic Devices I Purpose of the Lab
... 1) Connect the DFB laser to the OSA. 2) The settings of the OSA may need to be changed to make the graph look nicer. It is recommended that the number of sampling points be set to 250. This can be done by pressing SETUP, followed by SAMPLING POINTS and then typing in 250 and pressing nm/ENTER. Try t ...
... 1) Connect the DFB laser to the OSA. 2) The settings of the OSA may need to be changed to make the graph look nicer. It is recommended that the number of sampling points be set to 250. This can be done by pressing SETUP, followed by SAMPLING POINTS and then typing in 250 and pressing nm/ENTER. Try t ...
THE HANDYMAN`S GUIDE TO OSCILLOSCOPES (Part 1 of 2)
... • Focus - adjusts the beam for the thinnest and sharpest display. • VERT & HOR Position - controls the vertical and horizontal position of the display respectively • VERT V/div - controls the vertical sensitivity of the display, i.e., how many volts (or mV) per division. • HOR Sweep Speed - sets the ...
... • Focus - adjusts the beam for the thinnest and sharpest display. • VERT & HOR Position - controls the vertical and horizontal position of the display respectively • VERT V/div - controls the vertical sensitivity of the display, i.e., how many volts (or mV) per division. • HOR Sweep Speed - sets the ...
Broadband Communications over Power Lines (BPL)
... • Most systems use the HomePlug standard which provides protection for amateur frequencies ...
... • Most systems use the HomePlug standard which provides protection for amateur frequencies ...
Yellow nanosecond sum-frequency generating optical
... copper vapour lasers at 578 nm and dye lasers operating at 585 nm and 595 nm. These lasers are both bulky and inefficient and it would be attractive to develop a solid-state alternative to these lasers. One path that has been followed for the generation of yellow light is second harmonic generation ...
... copper vapour lasers at 578 nm and dye lasers operating at 585 nm and 595 nm. These lasers are both bulky and inefficient and it would be attractive to develop a solid-state alternative to these lasers. One path that has been followed for the generation of yellow light is second harmonic generation ...
Time Varying signals - Electrical and Computer Engineering
... Now select ‘Y2’ and move it to the bottom peak of the signal. The ‘Y ‘ gives the difference between the two cursors, which is in this case the voltage. 9. Use the horizontal ‘X’ cursors to measure the period in the same manner. The ‘X ‘ gives the time. 10. Using the Quickprint function, save the ...
... Now select ‘Y2’ and move it to the bottom peak of the signal. The ‘Y ‘ gives the difference between the two cursors, which is in this case the voltage. 9. Use the horizontal ‘X’ cursors to measure the period in the same manner. The ‘X ‘ gives the time. 10. Using the Quickprint function, save the ...