• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Download T3200 Datasheet
Download T3200 Datasheet

The Source Concept Considerations in a Protective Relay
The Source Concept Considerations in a Protective Relay

June, 2010
June, 2010

... Power set by input dynamic range (VREF), not core voltage FOM improves with more resolution (up to thermal noise limit) Can get rid of the ladder – size relays differently and get different Vpi’s ...
GSK-58 -- IR Toggle Switch GSK-58
GSK-58 -- IR Toggle Switch GSK-58

... person. These products are not suitable for children. Before connecting mains powered equipment to the relay outputs please check with the relevant authorities in order to ensure compliance with all current local safety requirements. Many areas of the assembly may operate at mains voltage. A suitabl ...
GSK-58 -- IR Toggle Switch GSK-58
GSK-58 -- IR Toggle Switch GSK-58

T3200 Insulation Monitoring Relay
T3200 Insulation Monitoring Relay

... actual insulation level, either by means of two instruments simultaneously indicating for both insulation systems (I and II), or by means of one instrument which can be connected to the two instrument outputs via a change-over switch. See connection diagram. ...
kk010 - installing of generator protection2009-08
kk010 - installing of generator protection2009-08

PS1: Overcurrent Protection of a Substation Power Transformer
PS1: Overcurrent Protection of a Substation Power Transformer

...  To develop a MATLAB program to solve a hydro-thermal coordination problem for a system consisting of one hydro plant and one thermal plant.  To evaluate the performance of the program by conducting experiments using the computers available in the lab. Students can conduct the experiments at any t ...
PR1-E SERIES 9kW, 12kW 18kW and 24kW HVAC RANGE 1
PR1-E SERIES 9kW, 12kW 18kW and 24kW HVAC RANGE 1

... The alarm circuit has voltage free relay contacts and are rated up to 2A @ 125V ac (RMS) load. The internal supply to the relay is obtained from the transformer via a 20mm 1A fuse. These are connected to the Live and Neutral supply and therefore the relay and LED can only energise when there is an o ...
REL08-MODULE : 8 OUTPUTS 16A/230V Technical Product
REL08-MODULE : 8 OUTPUTS 16A/230V Technical Product

... devices. The relay module has 8 potential-free, change over contacts which can each connect max 16A at 230V (cos=1). These are 8 independently working contacts that can each be allocated an individual function by means of the software. ...
Abstract - theelectromech.in
Abstract - theelectromech.in

... with a set of 12 volt DC relays in star mode first and then to delta mode by an electronically adjustable timer. A set of relays are used to shift the motor connections from star to delta with a time delay. The project is supplied with six lamps instead of a 3 phase motor i.e., two lamps representin ...
ECP 11-0224a Automatic Voltage Control Test Form
ECP 11-0224a Automatic Voltage Control Test Form

... or delay characteristic equation and applied voltage deviation (multiple of bandwidth) Measured time delay (measured by Stopwatch) ...
PS1: Overcurrent Protection of a Substation Power Transformer
PS1: Overcurrent Protection of a Substation Power Transformer

Full-text
Full-text

... Thus the most reliable evaluation can be determined after switching off powering impulse from relay windings on time interval t6 (fig. 3/b). Reliability is also due to the fact that the pulse amplitude is set to 40 ÷ 60V and duration t6 > t2. No additional current sensor requires for processing. It ...
Overcurrent Protection and Voltage Sag Coordination in Systems
Overcurrent Protection and Voltage Sag Coordination in Systems

... Internal combustion engines. ...
BE1-GPS Product Screenshow
BE1-GPS Product Screenshow

Power Pack and Auxiliary Relay — 120V/ 277V
Power Pack and Auxiliary Relay — 120V/ 277V

... The power pack employs a micro-controller that switches loads at minimum voltage, protecting relay contacts from high in-rush current common when switching electronic ballasts. This switching method reduces the stress across the relay contacts, preventing arc-over and assuring long reliable contact ...
eriii25_control_navigation8_relays
eriii25_control_navigation8_relays

PROTECTIVE RELAYING FOR TRANSMISSION AND
PROTECTIVE RELAYING FOR TRANSMISSION AND

... rodents into the equipment and human error in system operation. The capital investment put in a power system is large. To save this equipment from abnormal system running conditions and breakdowns generally known a “faults” and to ensure satisfactory operation of power supply system, constant watch ...
transformer protection
transformer protection

... winding cannot be detected by transverse differential protection as it does not disturb the balance between the currents in neutral and high voltage CTs.  For protection against inter-turn faults the following protection schemes are used. (1)Cross differential protection. (2)Residual voltage protec ...
NRD1-6_Rev.0110 - pes-psrc
NRD1-6_Rev.0110 - pes-psrc

ECP 11-0310 High Impedance Differential
ECP 11-0310 High Impedance Differential

H044023944
H044023944

EE 4003- Power Systems II - IESL e
EE 4003- Power Systems II - IESL e

... 1.3 Explain methods of earthing in sub-stations 3. Perform load flow calculations in electrical power systems 3.1. Form bus-admittance matrix 3.2. Apply Gauss – Zeidel and Newton-Raphson methods to calculate voltages at buses simple power system 3.3. Sketch power flow diagram 3.4. Familiarize with s ...
Document
Document

< 1 ... 55 56 57 58 59 60 61 62 63 ... 68 >

Protective relay



In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected. The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency. Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays. In many cases a single microprocessor relay provides functions that would take two or more electromechanical devices. By combining several functions in one case, numerical relays also save capital cost and maintenance cost over electromechanical relays. However, due to their very long life span, tens of thousands of these ""silent sentinels"" are still protecting transmission lines and electrical apparatus all over the world. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices, or one or two microprocessor relays.The theory and application of these protective devices is an important part of the education of an electrical engineer who specializes in power systems. The need to act quickly to protect circuits and equipment as well as the general public often requires protective relays to respond and trip a breaker within a few thousandths of a second. In these cases it is critical that the protective relays are properly maintained and regularly tested.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report