• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CENTRAL TESTING CIRCLE,DVC, MAITHON
CENTRAL TESTING CIRCLE,DVC, MAITHON

... There may be some ratio errors in CTs (upto 5%) and some difference in primary and secondary currents due to tap changing (upto 10%). Biasing is used to avoid false trippings from these effects. The differential protection uses some percentage of through current for biasing (or restraining). say we ...
Aalborg Universitet Margin against Cascading Events
Aalborg Universitet Margin against Cascading Events

Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

Protection Fundamentals - Levine Lectronics and Lectric
Protection Fundamentals - Levine Lectronics and Lectric

... meter and control power flow • Reactors - to limit fault current (series) or compensate for charge current (shunt) • VT and CT - to measure primary current and voltage and supply scaled down values to P&C, metering, SCADA, etc. • Regulators - voltage, current, VAR, phase angle, etc. ...
Aalborg Universitet Applications
Aalborg Universitet Applications

2008 26 Spring Wiring Matters
2008 26 Spring Wiring Matters

... both basic and fault protection. An example of an enhanced protective measure is reinforced insulation. Basic protection and fault protection are both provided by the reinforced insulation (Refer to Regulation 410.3.2). Recognized protective measures BS 7671: 2008 recognizes the protective measures ...
Sample Questions - C&G 2382 17th Edition 2382-10 full
Sample Questions - C&G 2382 17th Edition 2382-10 full

... 21 o/c 4 Which is a method of fault protection 1 out of reach 2 Reinforced insulation 3 Obstacles 4 Insulation of live parts 22 o/c4 The maximum disconnection time for a circuit supplied by a reduced low voltage system using a 110 V midpoint earthed transformer is a 0.2 second b 0.4 second c 1 secon ...
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

Design and construction of a numerical over current relay
Design and construction of a numerical over current relay

liuwg_workshop_31-07-2008_rd
liuwg_workshop_31-07-2008_rd

Modelo Apresentacao - Cigré Brasil
Modelo Apresentacao - Cigré Brasil

Galvanometer controlled recorder
Galvanometer controlled recorder

... said ?rst and second sensing means attached ‘to said measured, it forces contact element 32 against ‘either con bracket are moved into direct alignment with the shutter tact 33 or 34, depending upon whether the reading being measured moves the pointer upscale or downscale. When 15 connected to said ...
D1000 Arc-fault Protection System • Improve personnel safety
D1000 Arc-fault Protection System • Improve personnel safety

... The D1000 is a stand-alone and high speed arc protection unit for electrical power distribution systems. D1000 supports both point and fibre sensor technologies for arc flash detection and supports up to six sensors. The sensors can be combined in any combination, depending on the application and re ...
Considerations for Using High-Impedance or Low
Considerations for Using High-Impedance or Low

... starting a timer when the breaker trip is applied and detecting if the breaker interrupts current by the end of the fixed time delay. Establish the time delay according to the rated breaker interrupting time plus some small margin. The margin time depends, in part, on how fast the relay recognizes t ...
AN SB-220 COMPENDIUM
AN SB-220 COMPENDIUM

clemson university dg conference
clemson university dg conference

Switchyard - 123SeminarsOnly.com
Switchyard - 123SeminarsOnly.com

... Isolator with earth switches (ES):The instrument current transformer (CT) steps down the current of a circuit to a lower value and is used in the same types of equipment as a potential transformer. This is done by constructing the secondary coil consisting of many turns of wire, around the primary c ...
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

... protect the electrical network from these faults. ...
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

SPRECON -E-P DD..6-SERIES P D
SPRECON -E-P DD..6-SERIES P D

... The SPRECON-E-P DD..6 devices are multifunctional devices for protection, control and automation of energy stations. They can be applied as main protection units of overhead power transmission lines and cables of all grids and neutralpoint connections at medium or high voltage levels. Control of the ...
Circuit Breakers - Short Time Delay (STD)
Circuit Breakers - Short Time Delay (STD)

Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comparison Comment Rationale Matrix 2011-09-28 AESO AUTHORITATIVE DOCUMENT PROCESS

... R1 Each legal owner of a transmission facility, legal owner of a generating unit and legal owner of an aggregated generating facility must use one of the criteria set out in requirements R1.1 through R1.13, inclusive, for each specific circuit terminal to prevent its phase protective relay settings ...
1.0 overcurrent protection
1.0 overcurrent protection

II 777 HVR P2 B Installation Instructions
II 777 HVR P2 B Installation Instructions

... Trip Class. Determines how quickly the 777-HVR-P2 will trip when an overcurrent (overload) condition is detected. TC is a dual-function setting—both a thermal trip class (NEMA standard) and a linear trip delay (in seconds) can be set. While the standard trip classes are 5, 10, 15, 20, and 30, TC can ...
Protector
Protector

< 1 ... 26 27 28 29 30 31 32 33 34 ... 68 >

Protective relay



In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected. The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency. Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays. In many cases a single microprocessor relay provides functions that would take two or more electromechanical devices. By combining several functions in one case, numerical relays also save capital cost and maintenance cost over electromechanical relays. However, due to their very long life span, tens of thousands of these ""silent sentinels"" are still protecting transmission lines and electrical apparatus all over the world. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices, or one or two microprocessor relays.The theory and application of these protective devices is an important part of the education of an electrical engineer who specializes in power systems. The need to act quickly to protect circuits and equipment as well as the general public often requires protective relays to respond and trip a breaker within a few thousandths of a second. In these cases it is critical that the protective relays are properly maintained and regularly tested.