NC7WV16 TinyLogic ULP-A Dual Buffer
... The NC7WV16 is a dual buffer from Fairchild’s Ultra Low Power-A (ULP-A) series of TinyLogic. ULP-A is ideal for applications that require extreme high speed, high drive and low power. This product is designed for a wide low voltage operating range (0.9V to 3.6V VCC ) and applications that require m ...
... The NC7WV16 is a dual buffer from Fairchild’s Ultra Low Power-A (ULP-A) series of TinyLogic. ULP-A is ideal for applications that require extreme high speed, high drive and low power. This product is designed for a wide low voltage operating range (0.9V to 3.6V VCC ) and applications that require m ...
MAX792/MAX820 Microprocessor and Nonvolatile Memory Supervisory Circuits General Description
... Figure 4b or Figure 4c. RESET typically remains valid for VCC down to 2.5V; RESET is guaranteed to be valid with VCC down to 1V. Calculate the values for the resistor voltage divider in Figure 4b using the following equations: 1) R3 = (1.30 x VCC MAX)/(VLOW LINE x IMAX) 2) R2 = [(1.30 x VCC MAX)/(VR ...
... Figure 4b or Figure 4c. RESET typically remains valid for VCC down to 2.5V; RESET is guaranteed to be valid with VCC down to 1V. Calculate the values for the resistor voltage divider in Figure 4b using the following equations: 1) R3 = (1.30 x VCC MAX)/(VLOW LINE x IMAX) 2) R2 = [(1.30 x VCC MAX)/(VR ...
MAX6832–MAX6840 Ultra-Low-Voltage SC70 Voltage Detectors and µP Reset Circuits General Description
... that is being monitored at the IC’s VCC pin. However, some systems may use the open-drain output to levelshift from the monitored supply to reset circuitry powered by some other supply (Figure 5). Note that as the MAX6834/MAX6837/MAX6840’s V CC decreases, so does the IC’s ability to sink current at ...
... that is being monitored at the IC’s VCC pin. However, some systems may use the open-drain output to levelshift from the monitored supply to reset circuitry powered by some other supply (Figure 5). Note that as the MAX6834/MAX6837/MAX6840’s V CC decreases, so does the IC’s ability to sink current at ...
MAX16122–MAX16125 Dual Pushbutton Controllers in Tiny 6-Bump WLP Package General Description
... The MAX16122–MAX16125 pushbutton controllers with single-supply monitors monitor one or two pushbuttons and generate a hard reset signal if the buttons are pushed and held for a setup delay. These devices make it easy to “hide” the hard reset function in an existing pushbutton, such as a soft power ...
... The MAX16122–MAX16125 pushbutton controllers with single-supply monitors monitor one or two pushbuttons and generate a hard reset signal if the buttons are pushed and held for a setup delay. These devices make it easy to “hide” the hard reset function in an existing pushbutton, such as a soft power ...
FR-D700 INSTRUCTION MANUAL (Applied)
... z Before wiring or inspection, power must be switched OFF. To confirm that, LED indication of the operation panel must be checked. (It must be OFF.) Any person who is involved in wiring or inspection shall wait for at least 10 minutes after the power supply has been switched OFF and check that there ...
... z Before wiring or inspection, power must be switched OFF. To confirm that, LED indication of the operation panel must be checked. (It must be OFF.) Any person who is involved in wiring or inspection shall wait for at least 10 minutes after the power supply has been switched OFF and check that there ...
VARISPEED F7 USER`S MANUAL
... Setting the Power Supply Voltage Jumper (400 V Class Inverters of 75 kW or Higher) 4-3 Power ON ...................................................................................................................... 4-4 Checking the Display Status ..................................................... ...
... Setting the Power Supply Voltage Jumper (400 V Class Inverters of 75 kW or Higher) 4-3 Power ON ...................................................................................................................... 4-4 Checking the Display Status ..................................................... ...
EH Small Stone Phaser Issue J
... groups find it just the thing for producing eerie and spine-tingling background effects to accompany mystery or horror plays, and for the budding scientist or engineer, it is an ...
... groups find it just the thing for producing eerie and spine-tingling background effects to accompany mystery or horror plays, and for the budding scientist or engineer, it is an ...
$doc.title
... asynchronous master reset (MR). The oscillator configuration allows design of either RC or crystal oscillator circuits. The oscillator may be replaced by an external clock signal at input RS. In this case, keep the oscillator pins (RTC and CTC) floating. The counter advances on the negative-going tr ...
... asynchronous master reset (MR). The oscillator configuration allows design of either RC or crystal oscillator circuits. The oscillator may be replaced by an external clock signal at input RS. In this case, keep the oscillator pins (RTC and CTC) floating. The counter advances on the negative-going tr ...
4.5-V to 18-V, 20-A and 30-A SWIFT
... Frequency-setting resistor. Connect a resistor from this pin to AGND to program the switching frequency. ...
... Frequency-setting resistor. Connect a resistor from this pin to AGND to program the switching frequency. ...
Agilent 33500 Series Operating and Service Guide
... in the lower left corner of front panel. The instrument runs a power-on self test and then displays a message about how to obtain help, along with the current IP address. It also displays the GPIB address if the GPIB option is installed and enabled. The instrument's default function is a 1 kHz, 100 ...
... in the lower left corner of front panel. The instrument runs a power-on self test and then displays a message about how to obtain help, along with the current IP address. It also displays the GPIB address if the GPIB option is installed and enabled. The instrument's default function is a 1 kHz, 100 ...
FR-A500 INSTRUCTION MANUAL
... ! The [STOP] key is valid only when the appropriate function setting has been made. Prepare an emergency stop switch separately. ! Make sure that the start signal is off before resetting the inverter alarm. A failure to do so may restart the motor suddenly. A-3 ...
... ! The [STOP] key is valid only when the appropriate function setting has been made. Prepare an emergency stop switch separately. ! Make sure that the start signal is off before resetting the inverter alarm. A failure to do so may restart the motor suddenly. A-3 ...
14-Output Clock Generator with Integrated 2.0 GHz VCO AD9516-3
... The AD9516-3 features six LVPECL outputs (in three pairs) and four LVDS outputs (in two pairs). Each LVDS output can be reconfigured as two CMOS outputs. The LVPECL outputs operate to 1.6 GHz, the LVDS outputs operate to 800 MHz, and the CMOS outputs operate to 250 MHz. Each pair of outputs has divi ...
... The AD9516-3 features six LVPECL outputs (in three pairs) and four LVDS outputs (in two pairs). Each LVDS output can be reconfigured as two CMOS outputs. The LVPECL outputs operate to 1.6 GHz, the LVDS outputs operate to 800 MHz, and the CMOS outputs operate to 250 MHz. Each pair of outputs has divi ...
Chapter 8 : Machine maintenance
... (a) Check that the screws for the DC link connection cable (bar) are tight. (b) If a DC link low voltage alarm condition occurs in more than one module, see Subsection 3.1.4, "Alarm code 4" for explanations about how to troubleshoot the power supply module. (c) If a DC link low voltage alarm conditi ...
... (a) Check that the screws for the DC link connection cable (bar) are tight. (b) If a DC link low voltage alarm condition occurs in more than one module, see Subsection 3.1.4, "Alarm code 4" for explanations about how to troubleshoot the power supply module. (c) If a DC link low voltage alarm conditi ...
SR Mini HG SYSTEM Hardware Instruction Manual
... (It is not designed for use with medical equipment and nuclear energy.) z This is a Class A instrument. In a domestic environment, this instrument may cause radio interference, in which case the user may be required to take additional measures. z This instrument is protected from electric shock by r ...
... (It is not designed for use with medical equipment and nuclear energy.) z This is a Class A instrument. In a domestic environment, this instrument may cause radio interference, in which case the user may be required to take additional measures. z This instrument is protected from electric shock by r ...
FR-E500-KN INSTRUCTION MANUAL
... ! When parameter clear or all clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation. ! The inverter can be easily set for high-speed operation. Before changing its setting, fully examine the performances of the motor and machine. ...
... ! When parameter clear or all clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation. ! The inverter can be easily set for high-speed operation. Before changing its setting, fully examine the performances of the motor and machine. ...
J2 Series - Mitsubishi Electric Corporation
... been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine, passenger movement vehicles or under water relays, contact Mitsubishi. These produ ...
... been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine, passenger movement vehicles or under water relays, contact Mitsubishi. These produ ...
FR-A520-0.4K to 55K(-NA) FR-A540-0.4K to 55K(-NA
... When parameter clear or all clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation. The inverter can be easily set for high-speed operation. Before changing its setting, examine the performance of the motor and machine. In addition ...
... When parameter clear or all clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation. The inverter can be easily set for high-speed operation. Before changing its setting, examine the performance of the motor and machine. In addition ...
Mitsubishi A500 series manual
... When parameter clear or all clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation. The inverter can be easily set for high-speed operation. Before changing its setting, examine the performance of the motor and machine. In addition ...
... When parameter clear or all clear is performed, each parameter returns to the factory setting. Re-set the required parameters before starting operation. The inverter can be easily set for high-speed operation. Before changing its setting, examine the performance of the motor and machine. In addition ...
CMOS Analog Design Lecture Notes Rev 1.4L_1_07_09
... pMOS formed within a lightly doped n- material called the N-well nMOS formed within a lightly doped p- substrate Both types of transistors are four terminal devices The p-bulk connection is common throughout the integrated circuit and is connected to Vss (the most negative supply) Multiple n-wells c ...
... pMOS formed within a lightly doped n- material called the N-well nMOS formed within a lightly doped p- substrate Both types of transistors are four terminal devices The p-bulk connection is common throughout the integrated circuit and is connected to Vss (the most negative supply) Multiple n-wells c ...
Amplifier
An amplifier, electronic amplifier or (informally) amp is an electronic device that increases the power of a signal.It does this by taking energy from a power supply and controlling the output to match the input signal shape but with a larger amplitude. In this sense, an amplifier modulates the output of the power supply to make the output signal stronger than the input signal. An amplifier is effectively the opposite of an attenuator: while an amplifier provides gain, an attenuator provides loss.An amplifier can either be a separate piece of equipment or an electrical circuit within another device. The ability to amplify is fundamental to modern electronics, and amplifiers are extremely widely used in almost all electronic equipment. The types of amplifiers can be categorized in different ways. One is by the frequency of the electronic signal being amplified; audio amplifiers amplify signals in the audio (sound) range of less than 20 kHz, RF amplifiers amplify frequencies in the radio frequency range between 20 kHz and 300 GHz. Another is which quantity, voltage or current is being amplified; amplifiers can be divided into voltage amplifiers, current amplifiers, transconductance amplifiers, and transresistance amplifiers. A further distinction is whether the output is a linear or nonlinear representation of the input. Amplifiers can also be categorized by their physical placement in the signal chain.The first practical electronic device that amplified was the Audion (triode) vacuum tube, invented in 1906 by Lee De Forest, which led to the first amplifiers. The terms ""amplifier"" and ""amplification"" (from the Latin amplificare, 'to enlarge or expand') were first used for this new capability around 1915 when triodes became widespread. For the next 50 years, vacuum tubes were the only devices that could amplify. All amplifiers used them until the 1960s, when transistors appeared. Most amplifiers today use transistors, though tube amplifiers are still produced.