Download Sunmodule SW 50 Poly RGA Off

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Electrical ballast wikipedia , lookup

Decibel wikipedia , lookup

Power over Ethernet wikipedia , lookup

Wireless power transfer wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Opto-isolator wikipedia , lookup

Current source wikipedia , lookup

Power factor wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electrical substation wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Electrification wikipedia , lookup

Voltage regulator wikipedia , lookup

Islanding wikipedia , lookup

Electric power system wikipedia , lookup

Rectifier wikipedia , lookup

Audio power wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Shockley–Queisser limit wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Stray voltage wikipedia , lookup

Metadyne wikipedia , lookup

Surge protector wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power electronics wikipedia , lookup

Power engineering wikipedia , lookup

Buck converter wikipedia , lookup

Distribution management system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

AC adapter wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
SW 50 poly RGA
SW 50 POLY RGA
Datasheet
Produced in Germany,
the center for solar technology
TUV Power controlled:
Lowest measuring tolerance in industry
TUV Power controlled:
Lowest measuring tolerance
in industry
25 year linear
performance warranty and
10 year product warranty
25-year linear performance warranty
and 10-year product warranty
SolarWorld AG relies on Germany as its technology location, thereby ensuring sustainable product quality.
World-class quality
The TUV lines
Rheinland
Power controlled
inspection
mark and
guarantees
Fully-automated production
and seamless
monitoring
of the process
mate- that the nominal
power
for solar
modules
is inspected
atsites
regular
intervals and thus ensured.
rial ensure the quality
thatindicated
the company
sets as
its benchmark
for its
worldwide.
The deviation to TUV is maximum 2 percent.
SolarWorld Plus-Sorting
With its linear performance warranty covering a period of 25 years, SolarWorld guarPlus-Sorting guarantees highest system efficiency. SolarWorld only delivers modules
antees a maximum performance degression of 0.7% p.a., a significant added value
that have greater than or equal to the nameplate rated power.
compared to the two-phase warranties common in the industry. Therefore, the service certificate offers comprehensive protection for your investment in the long term.
25-year linear performance guarantee and extension of product warranty to 10 years
SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course
of 25 years, a significant added value compared to the two-phase warranties common in the industry. In addition, SolarWorld is offering a product warranty, which has
been extended to 10 years.*
*in accordance with the applicable SolarWorld Limited Warranty at purchase.
www.solarworld.com/warranty
solarworld.com
www.solarworld.com
geprüte
Sicherheit
SW 50 POLY RGA
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)*
Maximum power
Pmax
22.1 V
Open circuit voltage
Voc
18.1 V
Maximum power point voltage
Vmpp
3.02 A
Short circuit current
Isc
2.46 A
2.75 A
Maximum power point current
Impp
2.20 A
Maximum power
Pmax
50 Wp
Open circuit voltage
Voc
Maximum power point voltage
Vmpp
Short circuit current
Isc
Maximum power point current
Impp
Module efficiency
12.85 %
m
PERFORMANCE AT 800 W/m², NOCT, AM 1.5
*STC: 1000 W/m², 25°C, AM 1.5
1) Measuring tolerance (Pmax ) traceable to TUV Rheinland: +/- 2% (TUV Power Controlled).
THERMAL CHARACTERISTICS
35.5 Wp
19.7 V
16.1 V
Minor reduction in efficiency under partial load conditions at 25°C: at 200 W/m², 100%
(+/-2%) of the STC efficiency (1000 W/m²) is achieved.
COMPONENT MATERIALS
36
Cells per module
46 °C
NOCT
TC Isc
0.051 %/°C
TC Voc
-0.31 %/°C
TC Pmpp
-0.41 %/°C
-40°C to 85°C
Operating temperature
Poly crystalline
Cell type
Cell dimensions
2.04 in x 6.14 in (52 mm x 156 mm)
Front
Tempered glass (EN 12150)
Frame
Clear anodized aluminum
10.6 lbs (4.8 kg)
Weight
SYSTEM INTEGRATION PARAMETERS
1000 W/m²
I
SC
800 W/m²
1000 V
Maximum system voltage NEC
600 V
15 A
Maximum reverse current
2
Number of bypass diodes
600 W/m²
Module current [A]
Maximum system voltage SC II
Design Loads*
400 W/m²
Two rail system
113 psf downward
50 psf upward
*Please refer to the Sunmodule installation instructions for the details associated with
these load cases.
200 W/m²
100 W/m²
ADDITIONAL DATA
V
Module voltage [V]
OC
Power sorting 1
J-Box
Module type (UL 1703)
+/- 10 %
IP65
1
25.2 (640)
3.3 (86)
Ø 0.25 (6.6)
Ø 0.25 (6.6)
7.9 (200)
22.5
(572)
Ø 0.16 (0.41)
7.9 (200)
0.25
(6.6)
3.3 (86)
26.8 (680)
1.3 (34)
All units provided are imperial. SI units provided in parentheses.
SolarWorld AG reserves the right to make specification changes without notice.
SW-01-6110US 02-2015