Download cv 3-200 e - Europower Components Ltd

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Spark-gap transmitter wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Ground (electricity) wikipedia , lookup

Power engineering wikipedia , lookup

Stepper motor wikipedia , lookup

Current source wikipedia , lookup

Islanding wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Electrical ballast wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Ohm's law wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electrical substation wikipedia , lookup

Triode wikipedia , lookup

Metadyne wikipedia , lookup

Schmitt trigger wikipedia , lookup

History of electric power transmission wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Distribution management system wikipedia , lookup

Rectifier wikipedia , lookup

Power MOSFET wikipedia , lookup

Power electronics wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Buck converter wikipedia , lookup

Voltage regulator wikipedia , lookup

Opto-isolator wikipedia , lookup

Surge protector wikipedia , lookup

Alternating current wikipedia , lookup

Stray voltage wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Voltage Transducer CV 3-200
VPN =
140 V
For the electronic measurement of voltages: DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
0630
Electrical data
VPN
VPM
VS
KN
RL
CL
VC
IC
Primary nominal voltage rms
Primary voltage, measuring range
(Analog) secondary voltage @ VP maxi
Conversion ratio
Load resistance
Capacitive loading
Supply voltage (± 5 %)
Current consumption
140
0 .. ± 200
10
200 V / 10 V
≥1
≤5
± 15
32 + VS / R L
V
V
V
Overall accuracy @ VP maxi
VO
Offset voltage @ VP = 0
TA = 25°C
- 40°C .. + 85°C
TA = 25°C
- 40°C .. + 85°C
tr
Response time 1) to 90 % of VPN step
dv/dt dv/dt accurately followed
BW
Frequency bandwidth (- 1 dB) @ VPN
Maxi
± 0.2
± 0.6
± 5.0
± 13.0
0.3
200
DC .. 300
• Closed loop (compensated) voltage
transducer
kΩ
nF
V
mA
• Isolated plastic case recognized
according to UL 94-V0
• Patent pending.
Advantages
Accuracy - Dynamic performance data
XG
Features
%
%
mV
mV
µs
V/µs
kHz
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low thermal drift
Low response time
High bandwidth
High immunity to external
interference
• Low disturbance in common mode.
Applications
• AC variable speed drives and servo
General data
motor drives
TA
TS
P
R1
m
Ambient operating temperature
Ambient storage temperature
Total primary power loss
Primary resistance
Mass
Standards
- 40 .. + 85
°C
- 45 .. + 90
°C
3.1
W
6.4
kΩ
560
g
EN 50155: 1995
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Power supplies for welding
applications.
Application domain
Note:
1)
With a dv/dt of 200 V/µs.
• Traction.
Page 1/3
061219/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Current Transducer CV 3-200
Isolation characteristics
Vd
Ve
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10pC
6
2
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group I)
83.8
76.4
600
kV
kV
mm
mm
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
061219/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Dimensions CV 3-200
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal
Terminal
Terminal
Terminal
+
M
0
-
:
:
:
:
supply voltage + 15 V
measure
0V
supply voltage - 15 V
Connection
Top view
Mechanical characteristics
• General tolerance
• Transducer fastening
Fastening torque maxi
• Connection of primary
• Connection of secondary
Fastening torque maxi
Remarks
± 0.3 mm
3 holes ∅ 5.5 mm
M5 steel screws
3.8 Nm or 2.80 Lb. -Ft.
M5 threaded studs
M5 threaded studs
2.2 Nm or 1.62 Lb. -Ft.
• VS is positive when VP is applied on terminal +HT.
• CEM tested with a shielded secondary cable.
Shield connected to 0 V at both ends, or disconnected.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.