Download Overhead Aluminium Conductors

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Overhead Aluminium Conductor s
Aberdare, cables you can trust
Revised 012008
C O M PA N Y P R O F I L E
Aberdare Cables, a member of the Powertech Group, is a leading African manufacturer of cables and
distributor of electrical accessories. With manufacturing sites in three provinces of South Africa, and
offshore operations in Mozambique, Portugal and Spain, Aberdare Cables manufactures an extensive
range of electrical cables for application in power transmission, power distribution, rail, petrochemical,
mining, ports, airports, wholesale, construction and domestic building environments. Aberdare Cables
prides its self on its ability to identify and satisfy customer needs through development of innovative
products; unique, cost effective cable solutions for a wide range of industries. This and their extensive
project experience make them the supplier of choice for cable, electrical accessories (switches, sockets,
circuit breakers and reticulation) and special cable projects.
Technology focus
Aberdare Cables pursues on-going technology development programmes, and through active association
with its local and overseas affiliates, continues to remain at the forefront of technology.The company has
been recognised internationally as a pioneer in cable advancements. Aberdare serves on a number of
SABS and International Electro Technical Commission (IEC) cable working groups. As much as ten years
ago, in a move towards facilitating the provision of electricity for all countrywide, Aberdare Cables
designed products with an emphasis on cost efficiency of electrification.To this end, Aberdare created its
Electrodac range, which is aimed specifically at facilitating rural electrification by lowering the cost of
electricity delivery. More recently, in accordance with Siemens specifications, Aberdare produced an
unarmoured cable, with stringent fire characteristics, that was designed to reduce the propagation of fire
by cables.This cable is used at Eskom's open-cycle gas turbine generators at Mossel Bay and Atlantis.To
cater for international markets, Aberdare introduced fire survival cable with stringent properties that allow
continuous operation and circuit integrity for extended periods during a fire.
Quality focus
Aberdare Cables is a forerunner in the industry with regard to quality. The manufacturing, quality
assurance, testing and research resources of Aberdare are of a world-class standard. In fact, the company
was one of the first companies in South Africa to be awarded the South African Bureau of Standards
(SABS) Quality Assurance Certification, and has been ISO 9001 compliant for many years. Aberdare
Cables is UL listed and has Basec QA accreditation.
Transformation focus
Aberdare has embraced the empowerment concept. Today, Izingwe Consortium owns 30% of the
company and the company has assisted in the development of a number of black enterprises, such as
DRUMCO, the company that makes Aberdare Cable Drums. At Aberdare, education, training and
development are seen as a foundation for economic productivity and as crucial tools to build empowered
and dedicated employees. In this regard, the company actively promotes and follows a number of
education programmes, including adult education, apprentices, trainees, learnerships and formal
education assistance.
Aberdare Cables has always been an active supporter and pillar of strength for the communities in which it
operates. The company is championing a number of social investment initiatives across our country. The
biggest of these investments has been the continuous sponsorship of Sinethemba home for street
children in Port Elizabeth.
As a proudly South African company, Aberdare participated actively in the development of the ICT charter
and the draft DTI BBBEE codes. Aberdare will continue to adopt a proactive approach to effect the
transformation that the codes specify and to lead the cable industry in this regard. We enjoy a BBBEE
status of Level 3.
Index
Aberdare, cables you can trust
Overview
i-ii
ACSR
1
Canadian Standard Sizes
2-4
British Standard Sizes
5
Extra Strong
6
Australian Standard Sizes
7
Australian Standard Sizes, Extra Strong
7
South African Standard Sizes
8
AAC
9
British Standard Sizes
10
Canadian Standard Sizes
11
South African Standard Sizes
12
Australian Standard Sizes
12
AAAC
13
Australian Standard Sizes
14
British Standard Sizes
15
American Standard Sizes
16
Product Range
17
Over view
Aberdare, cables you can trust
Aluminium conductors have achieved wide acceptance all over the world for use in overhead
transmission and distribution lines. Generally a steel core is used with the aluminium to give
the conductor mechanical strength. This arrangement is termed Aluminium Conductor Steel
Reinforced or ACSR. Conductors comprised entirely of aluminium are known as All Aluminium
Conductors or AAC.These conductors are extensively used for busbars in outdoor substations
where spans are short. All Aluminium Alloy Conductors or AAAC consist of an alloying of
aluminium to give a tensile strength in excess of that of AAC, allowing longer spans. These
conductors are recommended for coastal areas where severe corrosion is a problem.
Hard drawn aluminium in H9 temper is used in both ACSR and AAC. High strain steel wire is
used in ACSR and this is sometimes protected from corrosion by an application of grease.
Such measures are particularly adopted when the conductor is intended for use in aggressive
environments as encountered in coastal regions.
Aberdare Power Cables Division manufactures a wide range of AAC, ACSR and AAAC to
customer’s requirements or national specifications.
The information contained in the following tables relates to the more popular sizes and
standards using the following conditions:
• AmbientTemperature
30°C
• Maximum ConductorTemperature
75°C
• Wind Speed
0,44m/s
• Normal StringingTemperature
25°C
• Solar Radiation
890W/m²
• Solar Absorption Coeficient
1
Sag and Tension charts are available on request. The following information to be
supplied:
• Span length
• Maximum design load (25% of UTS if not specified)
• Stringing temperature
i
Over view
Aberdare, cables you can trust
Comparison of Characteristics of Copper and Aluminium
Material
Copper
Aluminium
Al Alloy
8,89
2,70
2,70
367
160
-
Specific gravity
Tensile strength: MPa
Hard drawn
Annealed
Volume resistivity at 20°C Ω.m
248
100
295
1,724 x 10-8
2,826 x 10-8
3,253 x 10-8
Temperature coefficient of resistance per °C
0,00393
0,00403
0,00360
Coefficient of linear expansion per °C
17 x 10-6
23 x 10-6
23 x 10-6
Specific heat KJ/kg/K
0,394
0,904
0,904
Melting point °C
1083
658
658
Chemical Characteristics of Rod
Aluminium
Code
Si
99,7 EC
Fe
B
Mn+Ti+V+Cr
Al
% min.
-
0,16
0,003
-
99,65
% nom.
-
0,22
0,005
-
99,70
% max.
0,10
0,28
0,020
0,013
-
Alloy
Si
Mg
% min.
0,40
% nom.
0,45
Code
LA601/2
% max.
0,50
Fe
B
0,50
0,15
0,004
0,55
0,20
0,007
0,020
0,60
0,25
Mn+V+Cr
-
Ti
-
Zn
-
-
-
0,03
0,013
0,007
-
Others 0.01 max. - remainder aluminium
Mechanical Characteristics of Rod
Description
Tensile MPa
Elongation %
Aluminium
Alloy
110-130
170-200
6-12
8-12,5
6-12
8-12,5
Conductivity
62,3 min.
52,5 min.
Diameter mm
9,55 nom.
9,55 nom.
Firm/Association
Trade Name
Nearest Equivalents for SIMAG
Country
U.S.A
Canada
Switzerland
Aluminium Association
6201
Alcan
Arvidal
Alusuisse
Aldrey
VMW
Austria
Ranshofen
Elran
Berndorf
France
England
Pechiney
Almelec
Awco
Silmalec
ii
ACSR
Aluminium Conductor Steel Reinforced
1
2
85,01
85,01
95,60
95,60
107,20
107,20
107,20
126,70
126,70
126,70
152,00
152,00
152,00
152,00
159,40
WAXWING
PIPER
OSTRICH
ORIOLE
LINNET
MERLIN
CHICADEE
LARK
IBIS
PELICAN
FLICKER
HEN
HAWK
HERON
9,84
9,60
8,04
4,14
7,17
3,47
3,77
8,76
7,32
8,07
6,75
3,09
7,62
6,36
5,37
22,96
22,40
21,80
20,70
21,49
17,37
18,87
20,44
19,88
18,83
18,31
15,47
17,78
17,28
16,09
253,49
241,27
241,64
242,31
241,59
170,22
200,93
200,89
201,34
170,50
170,56
134,98
152,01
152,19
135,38
8,34
10,60
13,30
16,83
21,18
26,69
33,59
42,41
53,52
67,33
85,11
107,22
134,88
3,99
4,50
5,04
5,67
6,36
7,14
8,01
9,00
10,11
11,34
12,75
14,31
16,28
OWL
mm²
mm
mm
5,26
6,63
8,37
10,55
13,30
16,77
21,15
26,67
36,62
42,41
53,49
67,43
85,01
Aluminium
area
1,33
1,50
1,68
1,89
2,12
2,38
2,67
3,00
3,37
3,78
4,25
4,77
6,00
mm
6/1/1,33
6/1/1,50
6/1/1,68
6/1/1,89
6/1/2,12
6/1/2,38
6/1/2,67
6/1/3,00
6/1/3,37
6/1/3,78
6/1/4,25
6/1/4,77
26/2,57
+7/2,00
6/5,36
+7/1,79
18/1/3,09
30/7/2,54
26/2,73
+7/2,12
30/7/2,69
26/2,89
+7/2,25
18/1/3,47
18/1/3,77
30/7/2,92
26/3,14
+7/2,44
18/1/4,14
24/3,58
+7/2,39
30/7/3,20
26/3,44
+7/2,68
30/7/3,28
mm²
Overall
diameter
Diameter
over
steel
Stranding
and wire
diameter
Equival.
copper
area
WREN
WARBLER
TURKEY
THRUSH
SWAN
SWALLOW
SPARROW
ROBIN
RAVEN
QUAIL
PIGEON
PENGUIN
PARTRIDGE
Code name
59,15
56,30
39,49
13,46
31,40
9,46
11,16
46,88
32,73
39,78
27,83
7,50
35,47
24,71
17,62
1,39
1,77
2,22
2,81
3,53
4,45
5,60
7,07
8,92
11,22
14,19
17,87
21,99
mm²
Steel
area
22,90
29,20
36,60
46,30
58,30
73,40
92,40
117
147
185
234
295
373
372
373
421
421
472
472
470
555
557
557
669
668
668
669
702
153,00
142,48
187,48
176,90
210,28
198,39
179,68
212,09
247,77
234,07
255,77
272,99
297,57
281,13
312,64
Aluminium
9,73
12,37
15,52
19,64
24,71
31,14
39,19
49,48
62,44
78,55
99,30
125,09
156,87
mm²
Total
area
468
445
312
106
248
74,40
87,90
371
259
315
220
59
280
195
139
10,90
13,90
17,40
22,10
27,80
35,00
44,10
55,60
70,20
88,30
112
141
174
Steel
Mass kg/km
Total
1170
1110
981
775
916
544
643
928
816
787
692
432
701
616
511
33,80
43,10
54,00
68,40
86,10
108
137
173
217
273
346
436
547
108000
103000
84300
53800
75600
38300
44900
86300
71000
74200
61200
30800
66900
55200
43600
4100
4780
5600
6700
8080
9850
12100
15000
18700
23300
29300
36800
49800
Newton
Ultimate
tensile
strength
MPa
71100
65000
60500
57000
54500
52600
51200
50200
49400
49000
48600
48500
52400
47800
41900
55900
51500
55300
50900
41300
41000
54500
50100
40700
47300
53900
49500
53700
/C° x 10-6
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,37
19,90
21,44
18,43
19,38
18,43
19,37
21,44
21,44
18,43
19,38
21,44
19,91
18,43
19,36
18,43
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
83400
83400
77100
66200
73900
66200
66200
83400
77000
83400
77100
66200
83400
77000
76500
80400
80400
80400
80400
80400
80400
80400
80400
80400
80400
80400
80400
77100
MPa
Final
modulus
of
elasticity
0,1140
0,1198
0,1195
0,1189
0,1195
0,1686
0,1427
0,1438
0,1434
0,1695
0,1692
0,2126
0,1901
0,1897
0,2119
m
3000
3000
3000
3000
3000
3000
2500
2500
2000
1500
1500
1500
1500
1000
2000
2000
2000
2000
2000
2000
2000
1500
1500
1000
2000
2000
2000
2000
75
87
100
120
130
150
180
210
240
270
320
370
420
420
420
460
460
490
490
480
530
550
540
600
610
610
610
630
Standard
drum
length
A
Ω/km
3,4423
2,7062
2,1574
1,7046
1,3548
1,0750
0,8541
0,6766
0,5361
0,4261
0,3371
0,2676
0,2140
Current
rating
DC
resistance
at 20°C
Aluminium Conductor Steel Reinforced - ACSR (Canadian Standard Sizes)
3
mm
18/1/4,47
24/3,87
+7/2,58
30/7/3,46
26/3,72
+7/2,89
24/4,03
+7/2,69
26/3,87
+7/3,01
30/3,61
+19/2,16
54/7/2,69
18/1/4,78
24/4,14
+7/2,76
30/3,70
+19/2,22
26/3,97
+7/3,09
54/7/2,76
24/4,20
+7/2,82
54/7/2,82
30/3,92
+19/2,35
26/4,21
+7/3,28
54/7/2,92
45/3,38
+7/2,25
30/4,14
+19/2,48
26/4,44
+7/3,45
54/7/3,08
54/7/3,23
54/7/3,28
45/3,70
+7/2,47
mm²
177,40
177,40
192,80
192,80
192,80
192,80
197,04
202,70
202,70
202,70
202,70
212,30
212,30
228,00
228,00
228,00
253,40
253,40
253,40
253,40
278,70
286,80
304,00
EAGLE
DOVE
PEACOCK
SQUAB
TEAL
DUCK
KINGBIRD
ROOK
EGRET
GROSBEAK
GOOSE
FLAMINGO
GULL
REDWING
STARLING
CROW
TERN
MALLARD
DRAKE
CONDOR
CRANE
CANARY
RAIL
mm
22,33
23,22
24,22
23,55
24,21
24,54
25,25
24,21
23,90
24,82
25,90
25,15
24,84
25,38
25,38
27,43
26,68
26,28
27,00
28,96
28,11
27,76
29,11
29,51
29,59
4,47
7,74
10,38
8,67
8,07
9,03
10,80
8,07
4,78
8,28
11,10
9,27
8,28
8,46
8,46
11,75
9,84
8,76
6,75
12,40
10,35
9,24
9,69
9,84
7,41
Overall
diameter
(Std.)
mm
Diameter
over
steel
Stranding
and wire
diameter
177,40
177,40
Equival.
copper
area
OSPREY
PARAKEET
Code name
402,33
442,47
456,28
483,84
402,56
403,84
361,62
403,77
361,93
337,27
362,06
323,07
337,27
321,84
322,56
306,89
323,01
323,07
307,06
305,83
306,13
282,07
282,59
282,47
282,31
mm²
Aluminium
area
52,15
57,36
59,15
33,54
65,44
91,78
46,88
27,83
59,15
43,72
82,41
41,88
43,72
52,49
73,54
39,78
17,95
41,88
69,62
49,81
39,78
65,82
45,92
15,69
36,60
mm²
Steel
area
454,49
499,83
515,43
517,39
468,00
495,62
408,49
431,60
421,08
380,99
444,47
364,95
380,99
374,34
396,11
346,68
340.96
364,95
376,68
355,64
345,92
347,89
328,50
298,17
318,90
mm²
Total
area
1120
1230
1260
1340
1110
1120
1000
1120
1000
935
1000
895
932
891
894
851
896
893
851
847
846
781
782
780
780
Aluminium
412
453
468
265
517
728
371
220
468
346
654
331
346
415
583
315
142
331
552
394
315
520
363
124
289
Steel
Mass kg/km
1530
1680
1730
1610
1630
1850
1370
1340
1470
1280
1650
1230
1278
1310
1480
1170
1038
1224
1400
1240
1161
1300
1150
904
1069
Total
125000
137000
141000
117000
137000
170000
113000
98700
124000
106000
154000
102000
103000
111000
139000
97500
71320
99200
132000
105000
94400
119000
97400
62500
87300
Newton
Ultimate
tensile
strength
MPa
19,91
19,91
19,91
21,11
19,38
18,50
19,91
21,12
19,36
19,91
18,49
19,91
19,91
19,37
18,49
19,91
21,69
19,91
18,50
19,37
19,91
18,43
19,38
47500
47200
47100
42400
48400
53400
47800
42900
48600
48100
53800
48300
46500
48800
54200
48600
40400
46500
54400
48900
46700
53400
49000
40500
46800
/C° x 10-6
21,44
19,91
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
73200
73200
73200
66700
77000
81900
73200
66600
77100
73200
81900
73200
73800
77100
81900
73200
66200
73800
81800
77100
73900
83400
77000
66200
73800
MPa
Final
modulus
of
elasticity
A
0,0718
0,0653
0,0634
0,0598
0,0717
0,0716
0,0799
0,0718
0,0798
0,0857
0,0798
0,0895
0,0856
0,0897
0,0896
0,0942
0,0891
0,0894
0,0941
0,0944
0,0943
0,1024
0,1021
830
880
900
920
830
840
780
830
780
740
790
720
740
730
730
700
710
720
710
700
700
670
670
660
670
Ω/km
0,1018
0,1023
Current
rating
DC
resistance
at 20°C
Aluminium Conductor Steel Reinforced - ACSR (Canadian Standard Sizes)
2000
2000
2000
2000
1500
1000
1500
1500
1000
2000
1000
2000
1000
1000
1000
2000
2000
1500
1500
1500
1500
2000
1500
1500
2000
m
Standard
drum
length
4
mm
54/7/3,38
45/3,85
+7/2,57
54/7/3,52
45/4,00
+7/2,66
54/3,65
+19/2,19
45/4,14
+7/2/76
54/3,77
+19/2,27
45/4,27
+7/2,85
54/3,90
+19/2,34
45/4,40
+7/2,92
54/4,02
+19/2,41
45/4,53
+7/3,02
54/4,14
+19/2,48
45/4,65
+7/3,10
54/4,25
+19/2,55
45/4,77
+7/3,18
54/4,36
+19/2,62
84/3,70
+19/2,22
mm²
329,40
354,70
354,70
380,00
380,00
405,40
405,40
430,70
430,70
456,00
456,00
481,40
481,40
506,70
506,70
567,00
CURLEW
BLUEJAY
FINCH
BUNTING
GRACKLE
BITTERN
PHEASANT
DIPPER
MARTIN
BOBLINK
PLOVER
NUTHATCH
PARROT
LAPWING
FALCON
CHUKAR
mm
30,38
30,81
31,65
31,98
32,84
33,07
33,99
34,16
35,36
35,18
36,17
36,25
37,21
37,21
38,25
38,15
39,24
40,69
mm
10,56
7,98
10,95
8,28
11,35
8,55
11,70
8,76
12,05
9,06
12,40
9,30
12,75
9,54
13,10
11,10
Overall
diameter
(Std.)
10,14
7,71
Diameter
over
steel
Stranding
and wire
diameter
305,00
329,40
Equival.
copper
area
CARDINAL
ORTLAN
Code name
903,18
806,23
804,15
766,06
764,20
726,92
725,27
685,39
684,24
645,08
644,40
602,79
605,76
565,03
525,50
565,49
484,53
523,87
mm²
Aluminium
area
1340
1450
593,62
604,39
636,60
647,64
679,68
689,06
726,79
731,12
772,06
775,41
818,70
817,04
863,09
859,75
908,66
976,72
68,12
38,90
71,57
41,88
76,89
44,66
81,71
46,88
86,67
50,14
91,78
52,83
97,03
55,60
102,43
73,54
2497
2230
2220
2120
2110
2010
2010
1900
1890
1790
1780
1670
1680
1570
1460
1560
Aluminium
mm²
547,33
560,18
mm²
Total
area
62,81
36,31
Steel
area
2000
1870
2138
2010
2280
2130
2440
2260
2590
2410
2740
2530
2890
2660
3040
3080
539
308
568
331
610
353
648
371
687
396
728
418
770
440
813
583
Total
1840
1740
497
287
Steel
Mass kg/km
233000
246000
190000
234000
181000
222000
172000
210000
162000
199000
154000
187000
145000
176000
161000
135000
149000
126000
Newton
Ultimate
tensile
strength
MPa
46900
42200
46700
42000
47300
41900
47100
41900
46900
41700
46700
417,00
46500
41600
46400
41600
46400
43600
/C° x 10-6
19,91
21,11
19,91
21,13
19,97
21,12
19,95
21,11
19,97
21,13
19,97
21,12
19,97
21,12
19,97
21,12
19,96
20,85
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
67500
72300
66700
72300
66700
72200
66700
72300
66500
72300
66700
72300
66700
72300
73200
66600
73200
66700
MPa
Final
modulus
of
elasticity
A
0,0321
0,0359
0,0359
0,0377
0,0378
0,0398
0,0399
0,0422
0,0422
0,0448
0,0449
0,0480
0,0478
0,0512
0,0550
0,0513
1300
1300
1300
1200
1200
1200
1200
1100
1100
1100
1100
1100
1100
1000
980
1000
930
970
Ω/km
0,0597
0,0552
Current
rating
DC
resistance
at 20°C
Aluminium Conductor Steel Reinforced - ACSR (Canadian Standard Sizes)
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
2000
2000
1000
2000
2000
m
Standard
drum
length
5
151,80
161,85
194,94
226,20
261,54
293,86
326,12
399,98
462,63
422,60
431,18
529,84
484,48
588,46
537,66
596,99
744,84
747,96
20,06
30,62
36,88
42,80
49,48
55,60
61,70
75,67
87,53
48,50
49,48
100,24
55,60
111,33
61,70
68,51
83,11
60,60
131,74
131,23
158,06
183,41
212,06
238,27
264,42
324,31
375,11
374,11
381,70
429,60
428,88
477,13
475,96
528,49
661,73
687,36
15,89
16,52
18,13
19,53
21,00
22,26
23,45
25,97
27,93
26,73
27,00
29,89
28,62
31,50
30,15
31,77
35,50
35,58
5,73
4,72
7,77
8,37
9,00
9,54
10,05
11,13
11,97
8,91
9,00
12,81
9,54
13,50
10,05
10,59
11,80
9,96
80,65
96,77
112,90
129,00
145,20
161,30
193,50
225,80
225,80
225,80
258,10
258,10
290,30
290,30
322,60
414,63
430,70
TIGER
WOLF
LYNX
PANTHER
LION
BEAR
GOAT
SHEEP
ANTELOPE
BISON
DEER
ZEBRA
ELK
CAMEL
MOOSE
DINOSAUR
BERSFORD
80,65
COYOTE
148,21
16,84
131,37
15,81
5,25
80,65
LEOPARD
126,43
20,48
105,95
14,57
5,79
64,52
1,77
3,50
4,37
5,27
6,11
7,07
8,81
10,52
36,88
12,50
42,80
13,14
13,99
15,90
17,50
13,55
HYENA
mm²
12,37
24,48
30,62
36,88
42,80
49,48
61,70
73,65
100,10
87,53
116,16
91,97
97,91
111,33
122,48
118,53
mm²
mm²
6,45
12,90
16,30
19,35
22,58
25,81
32,26
38,71
38,71
45,16
45,16
48,39
51,61
58,06
64,52
64,52
10,60
20,98
26,25
31,61
36,68
42,41
52,88
63,13
63,22
75,02
73,36
78,83
83,92
95,43
104,98
104,98
mm
6/1/1,50
6/1/2,11
6/1/2,36
6/1/2,59
6/1/2,79
6/1/3,00
6/1/3,35
6/1/3,66
12/7/2,59
6/1/3,99
12/7/2,79
6/1/4,09
6/1/4,22
6/1/4.50
6/1/4,72
6/4,72
+7/1,57
7/4,39
+7/1,93
6/5,28
+7/1,75
26/2,54
+7/1,91
30/7/2,36
30/7/2,59
30/7/2,79
30/7/3,00
30/7/3,18
30/7/3,35
30/7/3,71
30/7/3,99
54/7/2,97
54/7/3,00
30/7/4,27
54/7/3,18
30/7/4,50
54/7/3,35
54/7/3,53
54/3,95
+19/2,36
48/4,27
+7/3,32
mm²
4,50
6,33
7,08
7,77
8,37
9,00
10,05
10,98
12,95
11,97
13,95
12,27
12,66
13,50
14,16
14,15
Total
area
mm
Steel
area
1,50
2,11
2,36
2,59
2,79
3,00
3,35
3,66
7,77
3,99
8,37
4,09
4,22
4,50
4,72
4,71
Aluminium
area
mm
Overall
diameter
(Std.)
Diameter
over
steel
Stranding
and wire
diameter
Equival.
copper
area
MOLE
SQUIRREL
GOPHER
WEASEL
FOX
FERRET
RABBIT
MINK
SKUNK
BEAVER
HORSE
RACCOON
OTTER
CAT
HARE
DOG
Code name
1906
364
438
508
588
660
733
899
1040
1040
1060
1190
1190
1320
1320
1460
1835
365
361
291
29,20
57,70
72,20
87,00
101
117
145
174
175
206
203
217
231
263
289
289
Aluminium
480
242
292
330
391
440
488
598
692
383
391
792
440
880
488
542
658
159
133
162
13,90
27,50
34,40
41,50
48,10
55,60
69,40
82,80
292
98,40
338
103
110
125
138
100
Steel
Mass kg/km
Total
2386
606
730
846
970
1100
1220
1500
1730
1420
1450
1980
1630
2200
1810
2000
2493
524
494
453
43,10
85,20
107
129
149
173
214
257
467
304
541
320
341
388
427
389
177650
58700
69200
79300
90800
101000
112000
136000
157000
117000
119000
179000
133000
199000
147000
162000
202920
47300
42200
41900
4780
8020
9610
11450
13100
15200
18500
21900
52900
25900
60700
27200
28900
32800
36000
34700
Newton
Ultimate
tensile
strength
MPa
20,68
18,43
18,43
18,43
18,43
18,43
18,43
18,43
18,43
19,91
19,91
18,43
19,91
18,43
19,91
19,91
19,91
19,54
19,54
18,93
43200
56900
55700
54900
54300
53900
53600
53100
52900
47700
47600
52800
47300
52700
47000
46700
46700
51900
47800
52400
65000
54600
52700
51500
50700
50200
49500
49100
71900
48800
71000
48700
48700
48500
48500
48800
/C° x 10-6
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,31
15,84
19,31
15,84
19,31
19,31
19,31
19,31
19,92
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
68800
83400
83400
83400
83400
83400
83400
83400
83400
73200
73200
83400
73200
83400
73200
73200
72200
76000
76300
82200
80400
80400
80400
80400
80400
80400
80400
80400
108000
80400
108000
80400
80400
80400
80400
76400
MPa
Final
modulus
of
elasticity
0,0420
0,2202
0,1828
0,1576
0,1363
0,1213
0,1093
0,0891
0,0770
0,0773
0,0757
0,0673
0,0674
0,0606
0,0607
0,0547
0,0437
0,3035
0,2184
0,2697
1132
420
470
520
560
610
650
730
800
790
800
870
860
930
920
980
1110
420
410
360
87
130
150
170
190
210
240
260
270
290
300
300
310
340
360
360
A
Ω/km
2,7062
1,3677
1,0933
0,9077
0,7822
0,6766
0,5426
0,4546
0,4571
0,3825
0,3939
0,3640
0,3419
0,3007
0,2733
0,2733
Current
rating
DC
resistance
at 20°C
Aluminium Conductor Steel Reinforced - ACSR (British Standard Sizes)
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
1500
2000
2000
2000
2000
2000
2000
3000
3000
3000
2500
2500
1500
1500
1500
2000
1500
2000
1500
1500
1500
1500
2000
m
Standard
drum
length
6
4,18
6,65
10,57
16,81
21,20
25,49
32,51
35,32
42,87
50,67
56,35
60,80
64,71
64,76
67,34
PETREL
MINORCA
LEGHORN
GUINEA
DOTTEREL
DORKING
AUK
BRAHMA
COCHIN
12,41
10,11
7,02
7,32
8,07
8,77
9,25
9,61
6,74
4,24
mm
mm
3/4/1,68
3/4/2,118
3/4/2,672
3/4/3,371
3/4/3,785
8/2,540
+1/4,242
12/7/2,339
12/7/2,441
12/7/2,690
12/7/2,924
12/7/3,084
12/7/3,204
8/4,046
+7/2,248
16/19/2,863
12/7/3,371
mm²
Diameter
over
steel
Stranding
and wire
diameter
Equival.
copper
area
BANTAM
MAGPIE
SHRIKE
SNIPE
LOON
GROUSE
Code name
mm²
8,83
14,13
22,45
35,68
44,97
14,13
30,07
32,77
39,81
46,92
52,29
56,39
27,80
91,80
62,40
mm²
6,65
10,58
16,84
26,71
33,74
40,52
51,61
56,13
68,19
80,58
89,61
96,71
102,80
103,00
107,10
11,71
12,22
13,46
14,63
15,42
16,03
14,83
18,14
16,87
Steel
area
5,03
6,35
8,03
10,11
11,35
9,32
Aluminium
area
mm
Overall
diameter
(Std.)
194,80
169,50
81,89
88,90
108,00
127,50
141,90
153,10
130,60
15,48
24,71
39,29
62,39
78,71
54,65
mm²
Total
area
285,50
295,10
142,10
154,70
188,00
222,10
246,90
266,30
282,10
18,21
28,90
46,00
73,20
92,30
111,20
Aluminium
Total
87,80
139,70
222,30
353,60
445,90
221,10
376,90
410,30
498,30
588,80
654,70
706,60
498,90
1005
782,40
Steel
69,59
110,80
176,30
280,40
353,60
109,60
234,80
255,60
310,30
366,70
407,80
440,30
216,70
719,50
487,30
Mass kg/km
122543
87396
43835
47719
57516
67567
73108
78874
49621
11679
18573
28547
43923
55300
23153
Newton
Ultimate
tensile
strength
MPa
14,22
15,30
15,30
15,30
15,30
15,30
15,30
15,30
17,64
115830
104800
104800
104800
104800
104800
104800
104800
86870
133760
133760
133760
133760
133760
93770
/C° x 10-6
13,68
13,68
13,68
13,68
13,68
16,92
Final
modulus
of
elasticity
Coefficient
of linear
expansion
Aluminium Conductor Steel Reinforced - ACSR (Extra Strong)
0,281
0,270
0,567
0,512
2,422
0,358
0,321
0,299
0,278
360
356
232
244
275
304
325
339
346
69
92
122
162
186
195
A
Ω/km
4,303
2,707
1,705
1,070
0,849
0,707
Current
rating
DC
resistance
at 20°C
1500
1500
2000
1500
2000
1500
2000
2000
2000
3000
3000
2500
2000
1500
1500
m
Standard
drum
length
7
17,50
21,00
24,50
27,00
29,25
31,50
33,75
42,75
7,50
9,00
10,50
9,00
9,75
10,50
11,25
14,25
1521,49
181,62
407,91
261,54
587,41
355,98 799,51
431,18 1057,31
506,04 1240,88
586,89 1439,13
671,96 1652,06
1078,12 2650,64
34,36
49,48
67,35
49,48
58,07
67,35
75,55
121,21
147,26
212,06
288,63
381,70
447,97
519,54
596,41
956,91
80,99
116,23
182,24
292,38
34,36
49,48
77,31
120,39
4,91
7,07
11,04
14,07
Aluminium
mm²
mm²
Total
area
mm²
Steel
area
29,45
42,41
66,27
106,32
Aluminium
area
962,41
271,79
391,39
532,74
391,38
459,33
532,74
599,87
38,59
55,57
86,77
111,01
Steel
Mass kg/km
Total
65000
90800
122000
119000
138000
159000
185000
10700
15000
22900
35500
Newton
3613,05 289000
679,70
978,80
1332,25
1448,69
1700,21
1971,87
2251,93
119,58
171,80
269,01
403,39
Ultimate
tensile
strength
MPa
20,0
18,4
18,4
18,4
19,9
19,9
19,9
20,0
46100
56100
54300
53400
47600
47100
46800
47100
51900
50200
49000
49000
/C° x 10-6
19,3
19,3
19,3
19,9
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
72300
83400
83400
83400
73200
73200
73200
72300
80400
80400
80400
76700
MPa
Final
modulus
of
elasticity
A
0,0302
0,1962
0,1363
0,1001
0,0757
0,0645
0,0556
0,0485
1380
445
558
676
795
877
960
1040
163
204
269
361
Ω/km
0,9742
0,6766
0,4330
0,2699
Current
rating
DC
resistance
at 20°C
1000
2000
2000
2000
2000
2000
2000
1000
3000
3000
3000
1000
m
Standard
drum
length
mm
mm
3/4/1,75
3/4/2,50
4/3/3,00
4/3/3,75
mm²
11,48
23,42
44,95
70,25
*
*
*
*
Diameter
over
steel
Stranding
and wire
diameter
Equival.
copper
area
5,25
7,50
9,00
11,25
mm
Overall
diameter
(Std.)
* Steel strands mixed in layer with aluminium strands
QUINCE
RAISIN
SULTANA
WALNUT
Code name
7,22
14,73
28,27
44,18
mm²
Aluminium
area
9,62
19,63
21,21
33,131
mm²
Steel
area
16,84
34,36
49,48
77,31
mm²
Total
area
19,78
38,99
77,46
121,05
Aluminium
75,61
154,29
166,71
260,40
Steel
Mass kg/km
Total
95,39
193,28
244,17
381,45
12700
24400
28300
43900
Newton
Ultimate
tensile
strength
MPa
133760
133760
122000
122000
MPa
-
/C° x 10-6
13,9
13,9
15,2
15,2
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
Final
modulus
of
elasticity
79
115
167
220
A
Ω/km
3,9377
1,9295
1,0048
0,6431
Current
rating
DC
resistance
at 20°C
3000
3000
3000
3000
m
Standard
drum
length
Aluminium Conductor Steel Reinforced - ACSR (Australian Standard Sizes) (Extra Strong Constructions)
PEACH
234,14
337,18
458,92
606,90
712,27
826,07
948,29
7,50
9,00
11,25
14,30
GRAPE
LEMON
LIME
MANGO
ORANGE
OLIVE
PAWPAW
mm
46,83
67,43
105,37
169,05
2,50
3,00
3,75
4,80
mm
6/1/2,50
6/1/3,00
6/1/3,75
6/4,75 &
7/1,60
30/7/2,50
30/7/3,00
30/7/3,50
54/7/3,00
54/7/3,25
54/7/3,50
54/3,75 &
19/2,25
54/4,75 &
19/2,85
mm²
mm
Overall
diameter
(Std.)
Diameter
over
steel
Stranding
and wire
diameter
Equival.
copper
area
ALMOND
APPLE
BANANA
CHERRY
Code name
Aluminium Conductor Steel Reinforced - ACSR (Australian Standard Sizes)
8
18,31
23,69
28,91
35,94
7,77
10,05
9,54
11,85
* Standard British Sizes
96,4
161
262
404
6,33
7,16
8,45
9,09
10,15
11,09
14,30
14,29
158/37
264/62
429/56
662/84
mm
2,11
2,36
2,79
3,00
3,35
3,66
4,72
4,71
mm
6/1/2,11
6/1/2,36
6/1/2,79
6/1/3,00
6/1/3,35
6/1/3,66
6/1/4,72
6/4,75
+7/1,57
30/7/2,59
30/7/3,35
54/7/3,18
54/3,95
+19/2,37
mm²
mm
Overall
diameter
(Std.)
Diameter
over
steel
Stranding
and wire
diameter
12,8
16,0
22,4
25,8
32,3
38,5
64,0
64,0
Equival.
copper
area
* 21/3,5
* 26/4,4
* 37/6,1
* 42/7,1
* 53/8,8
* 63/11
105/17
105/14
Code name
158
264
429
662
20,9
26,3
36,7
42,4
52,9
63,1
105
105
mm²
Aluminium
area
Aluminium
58
72
100
117
145
173
288
292
436
729
1185
1826
mm²
24,5
30,6
42,8
49,5
61,7
73,7
122
118
195
326
484
746
3,5
4,4
6,1
7,1
8,8
10,5
17,5
12,7
36,9
61,7
55,6
83,8
Total
area
mm²
Steel
area
Total
85
106
148
172
214
255
425
394
726
1214
1621
2489
Steel
27
34
48
55
69
83
137
102
290
485
436
663
Mass kg/km
69250
111400
131900
205500
7710
9610
13150
15200
18400
22500
36540
32640
Newton
Ultimate
tensile
strength
MPa
54600
52700
50700
50200
49500
49100
48500
48800
55700
53600
47300
46900
/C° x 10-6
19,31
19,31
19,31
19,31
19,31
19,31
19,31
19,92
18,43
18,43
19,91
19,96
Initial
modulus
of
elasticity
Coefficient
of linear
expansion
83400
83400
73200
72300
80400
80400
80400
80400
80400
80400
80400
76400
MPa
Final
modulus
of
elasticity
A
0,186
0,111
0,0687
0,0445
470
650
860
1123
130
150
190
210
240
260
360
360
Ω/km
1,395
1,116
0,798
0,690
0,553
0,463
0,278
0,278
Current
rating
DC
resistance
at 20°C
Aluminium Conductor Steel Reinforced - ACSR ( South African Standard Sizes)
2000
2000
1500
1000
3000
3000
2500
1500
1500
1500
1500
2000
m
Standard
drum
length
AAC
All Aluminium Conductor
9
10
MIDGE
APHIS
GNAT
WEEVIL
MOSQUITO
LADYBIRD
ANT
FLY
BLUEBOTTLE
EARWIG
GRASSHOPPER
CLEGG
WASP
BEETLE
BEE
CRICKET
HORNET
CATERPILLAR
CHAFER
SPIDER
COCKROACH
BUTTERFLY
MOTH
DRONE
LOCUST
CENTIPEDE
MAYBUG
SCORPION
CICADA
TARANTULA
BULL
Code name
mm
mm
7/2,06
3/3,35
7/2,21
3/3,66
7/2,59
7/2,79
7/3,10
7/3,40
7/3,66
7/3,78
7/3,91
7/4,17
7/4,39
19/2,67
7/4,90
7/5,36
19/3,25
19/3,53
19/3,78
19/3,99
19/4,22
19/4,65
19/5,00
37/3,58
19/5,36
37/3,78
37/4,09
37/4,27
37/4,65
37/5,23
61/4,25
mm²
14,19
16,13
16,13
19,35
22,58
25,81
32,26
38,71
45,16
48,39
51,61
58,06
64,52
64,52
80,64
96,77
96,77
112,90
129,00
145,20
161,30
193,50
225,80
225,80
258,10
258,10
290,30
322,60
387,10
483,90
527,87
6,18
7,24
6,63
7,91
7,77
8,37
9,30
10,20
10,98
11,34
11,73
12,51
13,17
13,35
14,70
16,08
16,25
17,65
18,90
19,95
21,10
23,25
25,00
25,06
26,80
26,46
28,63
29,89
32,55
36,61
38,25
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
kg/km
64,00
72,70
73,70
86,80
101
117
145
174
202
216
231
262
291
293
362
434
435
513
588
655
733
890
1030
1030
1180
1150
1340
1460
1740
2200
2400
mm²
Mass
23,33
26,44
26,85
31,56
36,88
42,80
52,83
63,55
73,65
78,55
84,05
95,60
105,95
106,38
132,00
157,95
157,95
185,95
213,22
237,57
265,75
322,66
373,06
372,44
428,72
415,22
486,11
529,84
628,34
794,87
865,36
Aluminium
area
MPa
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
Newton
4340
4340
4860
5130
6360
7250
8770
10400
12000
12700
13600
15400
17000
18200
21000
25100
26000
30300
34500
38300
42700
51500
59400
60600
68200
67200
78200
85000
100000
126000
139000
52400
50000
52400
60000
52400
52400
52400
52400
52400
52400
52400
52400
52400
49650
52400
52400
49650
49650
49650
49650
49650
49650
49650
48250
49650
48250
48250
48250
48250
48250
46200
Initial
modulus
of
elasticity
Ultimate
tensile
strength
Coefficient
of linear
expansion
61000
69000
61000
69000
61000
61000
61000
61000
61000
61000
61000
61000
61000
59650
61000
61000
59650
59650
59650
59650
59650
59650
59650
58600
59650
58600
58600
58600
58600
58600
57570
MPa
Final
modulus
of
elasticity
All Aluminium Conductor - AAC (British Standard Sizes)
m
3000
3000
3000
3000
2500
2500
2500
2500
2500
2500
2000
1500
1500
2000
1000
1000
2000
2000
2000
1500
1500
1000
1000
1000
2000
1000
1000
1000
1000
1000
1000
A
139
154
152
172
185
203
231
259
284
296
308
334
356
358
408
456
457
506
551
589
632
713
779
779
849
833
918
967
1070
1230
1300
1,2271
1,0810
1,0662
0,9078
0,7763
0,6690
0,5419
0,4505
0,3887
0,3644
0,3406
0,2995
0,2702
0,2704
0,2169
0,1813
0,1825
0,1547
0,1349
0,1211
0,1083
0,0892
0,0771
0,0774
0,0671
0,0694
0,0593
0,0544
0,0459
0,0363
0,0334
Ω/km
Standard
drum
length
Current
rating
DC
resistance
at 20°C
11
ROSE
LILY
IRIS
PANSY
POPPY
ASTER
PHLOX
OXLIP
DAISY
PEONY
TULIP
CANNA
COSMOS
ZINNIA
DAHLIA
ORCHID
VIOLET
PETUNIA
ARBUTUS
ANEMONE
MAGNOLIA
BLUEBELL
MARIGOLD
HAWTHORN
NARCISSUS
COLUMBINE
CARNATION
GLADIOLUS
COREOPSIS
Code name
kg/km
58,00
73,00
92,10
116
147
185
233
294
371
419
470
554
665
699
775
891
1000
1050
1110
1220
1340
1440
1560
1670
1790
1900
2010
2110
2230
mm²
21,12
26,61
33,54
42,18
53,52
67,35
84,91
106,92
135,25
151,85
170,48
200,99
241,15
253,30
281,08
322,24
362,11
378,71
402,14
442,00
483,74
522,42
563,65
603,78
645,29
684,55
724,97
762,72
805,36
mm
5,88
6,60
7,41
8,31
9,36
10,50
11,79
13,23
14,88
15,95
16,90
18,35
20,10
20,60
21,70
23,31
24,71
25,27
26,04
27,30
28,56
29,68
30,87
31,95
33,03
34,02
35,01
35,91
36,90
mm
7/1,96
7/2,20
7/2,47
7/2,77
7/3,12
7/3,50
7/3,93
7/4,41
7/4,96
19/3,19
19/3,38
19/3,67
19/4,02
19/4,12
19/4,34
37/3,33
37/3,53
37/3,61
37/3,72
37/3,90
37/4,08
37/4,24
61/3,43
61/3,55
61/3,67
61/3,78
61/3,89
61/3,99
61/4,10
mm²
Mass
13,30
16,77
21,15
26,67
33,62
42,41
53,50
67,43
85,01
95,59
107,21
126,69
152,01
159,38
177,40
202,70
228,01
239,00
253,39
278,71
304,09
329,29
354,72
380,02
405,41
437,72
456,01
481,42
506,71
Aluminium
area
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
MPa
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
Newton
4020
4830
5860
7150
8870
11000
13700
17100
21600
25100
27900
32600
38900
40700
45100
52900
59000
61600
65200
71400
77800
83900
92200
98400
105000
111000
117000
123000
130000
52400
52400
52400
52400
52400
52400
52400
52400
52400
49650
49650
49650
49650
49650
49650
48250
48250
48250
48250
48250
48250
48250
46200
46200
46200
46200
46200
46200
46200
Initial
modulus
of
elasticity
Ultimate
tensile
strength
Coefficient
of linear
expansion
61000
61000
61000
61000
61000
61000
61000
61000
61000
59650
59650
59650
59650
59650
59650
58600
58600
58600
58600
58600
58600
58600
57570
57570
57570
57570
57570
57570
57570
MPa
Final
modulus
of
elasticity
m
5000
5000
5000
2000
2000
2000
2000
2000
2000
1500
2000
2000
2000
2000
2000
2000
2000
2000
2000
1500
1500
1000
1000
1000
1000
1000
1000
1000
1000
A
130
150
170
200
230
270
310
360
410
450
480
530
590
610
650
710
770
790
820
870
910
960
1000
1050
1100
1130
1170
1200
1240
Ω/km
1,3555
1,0759
0,8535
0,6787
0,5349
0,4251
0,3372
0,2678
0,2117
0,1894
0,1687
0,1431
0,1193
0,1136
0,1023
0,0895
0,0796
0,0761
0,0717
0,0652
0,0596
0,0552
0,0513
0,0479
0,0448
0,0422
0,0399
0,0379
0,0359
Standard
drum
length
Current
rating
DC
resistance
at 20°C
All Aluminium Conductor - AAC (Canadian Standard Sizes)
12
68
106
159
273
434
745
888
1145
1454
1891
2402
24,7
38,6
58,1
99,8
157,6
270,8
322,7
415,2
527,4
684,6
869,4
6,42
8,03
10,15
12,91
16,92
21,52
23,49
26,73
30,12
34,36
38,73
GEMINI
JUPITER
LEO
LIBRA
MARS
MERCURY
MOON
NEPTUNE
PLUTO
SATURN
TAURUS
TRITON
URANUS
VENUS
VIRGO
Code name
4120
6120
8820
14600
23400
38800
46200
59900
75600
96600
122000
Newton
Ultimate
tensile
strength
Initial
modulus
of
elasticity
MPa
52400
52400
52400
52400
49650
49650
49650
48250
48250
46200
46200
Coefficient
of linear
expansion
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
61000
61000
61000
61000
59650
59650
59650
58600
58600
57570
57570
MPa
Final
modulus
of
elasticity
mm²
16,84
27,83
34,36
49,48
77,31
111,33
124,04
157,62
209,85
261,54
336,69
408,65
506,04
673,72
1447,29
mm
5,25
6,75
7,50
9,00
11,25
13,50
14,25
16.25
18,75
21,00
23,75
26,25
29,25
36,75
49,50
mm
7/1,75
7/2,25
7/2,50
7/3,00
7/3,75
7/4,50
7/4,75
19/3,25
19/3,75
37/3,00
19/4,75
37/3,75
61/3,25
61/3,75
91/4,50
mm²
26,61
43,97
54,29
78,18
122,15
175,90
195,98
249,04
331,56
413,23
531,97
645,67
799,54
1064,48
2286,72
Aluminium
area
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
46
76
94
136
213
307
342
435
579
722
929
1128
1397
1859
3995
kg/km
Mass
Initial
modulus
of
elasticity
MPa
52400
52400
52400
52400
52400
52400
52400
49650
49650
48250
49650
48250
46200
46200
46200
Coefficient
of linear
expansion
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
Newton
3400
5010
5980
8260
12500
17800
19800
26000
34000
43700
53700
66200
83400
109000
232000
Ultimate
tensile
strength
61000
61000
61000
61000
61000
61000
61000
59650
59650
58600
59650
58600
57570
57570
57570
MPa
Final
modulus
of
elasticity
m
5000
5000
5000
2000
2000
2000
2000
2000
2000
2000
2000
2000
1000
1000
1000
Current
rating
A
120
160
180
220
300
370
390
460
550
620
730
820
940
1130
1710
DC
resistance
at 20°C
Ω/km
1,7003
1,0286
0,8332
0,5786
0,3703
0,2572
0,2308
0,1825
0,1371
0,1102
0,0854
0,0706
0,0571
0,0429
0,0200
Standard
drum
length
m
3000
2500
2500
1500
2000
1500
1000
1000
1000
1000
1000
A
144
190
247
343
457
640
713
833
967
1130
1300
1,182
0,756
0,503
0,293
0,196
0,108
0,0909
0,0708
0,0558
0,0431
0,0339
Ω/km
Standard
drum
length
Current
rating
DC
resistance
at 20°C
All Aluminium Conductors - AAC (Australian Standard Sizes)
kg/km
mm²
mm
mm
7/2,12
7/2,65
7/3,25
7/4,26
19/3,25
19/4,26
19/4,65
37/3,78
37/4,26
61/3,78
61/4,26
15,6
24,3
36,6
62,9
99,4
171,0
203,5
262,0
332,6
431,8
548,3
Mass
mm²
Aluminium
area
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
* Standard British sizes
† Standard Canadian sizes
25
39
58
100
* 158
271
* 323
* 415
* 527
† 685
* 869
Code name
All Aluminium Conductors - AAC (South African Standard Sizes)
AAAC
All Aluminium Alloy Conductor
13
14
AGATE
AMETHYST
DIAMOND
EMERALD
GARNET
JADE
JASPER
OPAL
PEARL
RUBY
RUTILE
SAPPHIRE
SPINEL
TOPAZ
ZIRCON
Code name
mm²
16,84
27,83
34,36
49,48
77,31
111,3
124,0
157,6
209,8
261,5
336,7
408,7
506,0
673,7
1447,3
mm
5,25
6,75
7,50
9,00
11,30
13,5
14,3
16,3
18,8
21,0
23,8
26,3
29,3
33,8
49,5
mm
7/1,75
7/2,25
7/2,50
7/3,00
7/3,75
7/4,50
7/4,75
19/3,25
19/3,75
37/3,00
19/4,75
37/3,75
61/3,25
61/3,75
91/4,50
mm²
9,0
14,8
18,2
26,2
41,0
59,0
65,8
83,6
111,0
138,7
178,6
216,8
268,4
357,4
769,8
Aluminium
area
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
46
76
94
135
211
304
339
433
577
720
925
1125
1400
1863
4003
kg/km
Mass
Initial
modulus
of
elasticity
MPa
52400
52400
52400
52400
52400
52400
52400
49650
49650
48250
49650
48250
46200
46200
46200
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
Newton
4724
7800
9630
13900
21700
31200
34800
44200
58800
73300
94400
114500
141800
189000
406000
Ultimate
tensile
strength
Coefficient
of linear
expansion
61000
61000
61000
61000
61000
61000
61000
59650
59650
58600
59650
58600
57570
57570
57570
MPa
Final
modulus
of
elasticity
Current
rating
A
106
147
167
209
276
346
371
430
513
588
689
776
889
1056
1630
DC
resistance
at 20°C
Ω/km
1,952
1,18
0,958
0,665
0,426
0,296
0,265
0,210
0,158
0,127
0,0982
0,0811
0,0650
0,0490
0,0230
All Aluminium Alloy Conductors - AAAC (Australian Standard Sizes)
3000
3000
2500
2500
2000
1000
1000
2000
2000
2000
1000
2000
2000
2000
1000
m
Standard
drum
length
15
ACACIA
ALMOND
CEDAR
35
FIR
HAZEL
PINE
70
WILLOW
80
90
OAK
100
MULBERRY
ASH
ELM
POPLAR
225
SYCAMORE
UPAS
350
YEW
Code name
mm
mm
7/2,08
7/2,34
7/2,54
7/2,77
7/2,95
7/3,30
7/3,61
7/3,91
7/4,04
7/4,19
7/4,45
7/4,65
19/2,82
19/3,18
19/3,48
19/3,76
37/2,87
37/3,05
37/3,23
37/3,53
37/3,81
37/4,06
mm²
13
16
19
22
25
32
38
45
48
51
58
63
63
80
96
112
119
143
161
192
224
254
6,24
7,02
7,59
8,31
8,85
9,90
10,83
11,73
12,12
12,57
13,35
13,95
14,10
15,90
17,40
18,80
20,09
21,35
22,61
24,71
26,67
28,42
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
kg/km
65
82
97
115
131
164
196
230
245
264
298
325
326
415
497
580
660
744
835
997
1162
1319
mm²
Mass
23,79
30,10
35,47
42,18
47,84
59,87
71,65
84,05
89,73
96,52
108,9
118,9
118,7
150,9
180,7
210,9
239,4
270,3
303,2
362,1
421,8
479,0
Aluminium
area
6690
8440
9960
11860
13430
16820
20200
23630
25200
27060
30400
33330
33330
42350
50690
59220
67350
75780
85000
101670
118430
134510
Newton
Ultimate
tensile
strength
Initial
modulus
of
elasticity
MPa
52500
52400
52400
52400
52400
52400
52400
52400
52400
52400
52400
52400
49650
49650
49650
49650
48250
48250
48250
48250
48250
48250
Coefficient
of linear
expansion
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
23
m
3000
2500
2500
2500
2500
2500
2500
2000
1500
1500
1000
1000
2000
2000
2000
2000
2000
2000
2000
2000
1500
1500
A
133
153
169
189
204
235
262
290
302
316
339
359
359
416
467
513
551
600
643
718
789
853
Ω/km
1,39
1,10
0,934
0,785
0692
0,553
0,462
0,394
0,369
0,343
0,306
0,279
0,280
0,221
0,184
0,158
0,139
0,123
0,110
0,0921
0,0791
0,0696
MPa
61000
61000
61000
61000
61000
61000
61000
61000
61000
61000
61000
61000
59650
59650
59650
59650
58600
58600
58600
58600
58600
58600
Standard
drum
length
Current
rating
DC
resistance
at 20°C
Final
modulus
of
elasticity
All Aluminium Alloy Conductors - AAAC (British Standard Sizes)
16
ALTON
AMES
AZUZA
ANAHEIM
AMHERST
ALLIANCE
BUTTE
CANTON
CAIRO
DARIEN
ELGIN
FLINT
GREELY
Code name
kg/km
68
107
171
215
272
342
436
549
650
780
910
1031
1293
mm²
24,71
39,19
62,44
78,55
99,30
125,09
115,86
200,0
236,4
283,7
331,0
374,5
469,6
mm
6,36
8,01
10,11
11,34
12,75
14,31
16,30
18,30
19,90
21,80
23,55
25,13
28,14
mm
7/2,12
7/2,67
7/3,37
7/3,78
7/4,25
7/4,77
19/3,26
19/3,66
19/3,98
19/4,36
19/4,71
37/3,59
37/4,02
mm²
Mass
13,1
20,8
33,1
42
53
66
84
106
125
150
176
199
249
Aluminium
area
Overall
diameter
Stranding
and wire
diameter
Equival.
copper
area
7850
12550
19900
24020
30290
38140
48800
59100
69700
83600
97650
108500
136000
Newton
Ultimate
tensile
strength
Initial
modulus
of
elasticity
MPa
52400
52400
52400
52400
52400
52400
49650
49650
49650
49650
49650
48250
48250
Coefficient
of linear
expansion
/C° x 10-6
23
23
23
23
23
23
23
23
23
23
23
23
23
61000
61000
61000
61000
61000
61000
59650
59650
59650
59650
59650
58600
58600
MPa
Final
modulus
of
elasticity
m
3000
2500
2500
2500
1000
1000
2000
2000
2000
1000
1000
2000
1500
A
147
196
262
302
349
403
468
541
599
671
739
799
918
Ω/km
1,14
0,714
0,448
0,356
0,283
0,224
0,177
0,140
0,119
0,099
0,0848
0,0746
0,0595
Standard
drum
length
Current
rating
DC
resistance
at 20°C
All Aluminium Alloy Conductors - AAAC (American Standard Sizes)
Product Range
Our Services are Wide but Specialised
The Aberdare Group's product range and services are wide but specialised. Tried and tested and carrying South African
Bureau of Standards (SABS) marks and complying with International Standards, we stand by our products.
Impregnated Paper Cable
• 1 kV - 33 kV
• Fully impregnated, general purpose, heavy-duty or Drained
• Copper or aluminium conductors
• 1-5 core
• Armoured or unarmoured
MV XLPE-Insulated Cables
• XLPE-insulated, 3,8/6,6 kV to 19/33 kV
• Copper or aluminium conductors
• 1-core or 3-core
• Armoured or unarmoured
Bells Cable
• PVC-insulated, 600/1000 V
• 1-7 core
• Armoured or unarmoured
• With or without enhanced fire performance
Mains Cable
• PVC or XLPE-insulated 600/1000 V and 1900/3300 V
• 1-7 core
• Standard or concentric lay
• Armoured or unarmoured
• With or without enhanced fire performance
Electrodac Cable
• Airdac CNE 600/1000 V with and without auxiliary cores
• Airdac SNE 600/1000 V with and without auxiliary cores
• Interdac III 1,9/3,3 kV
• Airfield ligfhting 5 kV
General Wires & Cable Insulated (GWCI)
• Slipdac cable 600/1000 V
• HQR high temperature cable 300/500 V
• Panel/Cubicle cable 300/500 V
• PVC cords 300/300 V and 300/500 V
• Flexible PVC cable 450/750 V and 600/1000 V
• PVI cable 450/750 V and 600/1000 V
• Surfix 300/500 V
• Flat wiring cable 300/500 V
• Autocord 100 V
• Illumination cable 300/500 V and 450/750 V
• AudioRip cord 300/300 V
General Wires and Conductors Bare
• Copper, annealed, HD, tinned, Class 1, 2, 5 and 6
• Aluminium, hard drawn, Class 1 or 2
Aerial Bundled Conductors (ABC)
• Supporting-core type 600/1000 V
• Self-supporting type 600/1000 V
• Service-connection type 600/1000 V
• MV ABC cable 3,8/6,6 to 19/33 kV
Elastomeric Cable
• H05RR-F 300/500 V
• H05RRN-F 300/500 V
• H07RN-F 450/750 V
• Trackless Mining 640/1100 V
• Type 41 Mining 640/1100 V
• Type 61A Reeling 640/1100 V
• Type 61 B non-reeling 640/1100 V
• Type 63 Reeling 1900/3300 V
• MV Trailing 3,8/6,6 kV to 19/33 kV
• Locomotive to 6 kV
• Welding 100 V
Silicone Cable
• Multicore Cabtye 300/500 V
• 1-core unbraided 180 ºC 300/500 V
• 1-core braided 250 ºC 300/500 V
PVC-Nitrile Cable
• 1-core and sheathed 600/1000 V
• Welding cable 100 V
• Flexible Trailing cable 600/1000 V
Overhead Conductor
• Aluminium conductored steel reinforced (ACSR)
• All aluminium conductor (AAC)
• All aluminium alloy conductor (AAAC)
• XLPE or PVC covered ACSR, AAC, AAAC
Signalling & Control Multicore Cable
• PVC-insulated
• 7-37 core
• Armoured or unarmoured
• With or without added fire performance
Related documents