Quick and easy to apply, the Infinity® MCable®-Analog/Sync
exports analog output data (ECG or IBP) or QRS synchronization
data (ECG) parameter signals from the Infinity® M540 to an
external device. This accessory supports a QRS sync output
connection and two analog output channels, integrated into
a single analog connector to reduce cable clutter.
D-19709-2009
Infinity® MCable®-Analog/Sync
FEATURES
– Supports QRS sync output connection to synchronize defibrillators to the patient’s heartbeat
– Supports analog output of the primary ECG and arterial pressure signals
– Connects to the monitor or a Y-cable for simultaneous use with the Infinity MCable-Mainstream CO2
– Part of the accessory portfolio of Infinity® Acute Care System monitoring
TECHNICAL DATA
PRODUCT SPECIFICATIONS
Analog Output
SignalsECG, arterial blood pressure (ART)
Maximum delay ≤38 ms
Output range ±4.95 V ±5%
Signal gain: ECG: 1,000 (1V/mV), ART: 10 mV/mmHg
Gain accuracy ±20 mV or ±2%
Maximum offset ±10 mV
ECG bandwidth 0.5 to 40 Hz
IBP bandwidth DC to 16 Hz
Pacemaker pulses Amplitude: 5 V (nominal)
Duration: 4 ms
ECG range -5 to 5 mV
Pressure range -500 to 500 mmHg (1 V/100 mmHg)
-66.6 to 66.6 kPa (1 V/13.3 kPa)
Output impedance 200 Ω ±5%
Data rate
250 samples/sec
D-19896-2009
The sync pulse derived from detection of a QRS complex allows for synchronization of defibrillators to the
patient’s heartbeat during cardioversion. The two analog output channels are assigned to primary ECG and
arterial invasive pressure, enabling connection to external devices such as a balloon pump. This accessory
can be connected directly to the Infinity M540 monitor or to a Y-cable when used with the Infinity®
MCable®-Mainstream CO2.
Infinity® MCable®-Analog/Sync
Exports analog output or QRS
synchronization data
INFINITY® MCABLE®-ANALOG/SYNC
CONTINUING TECHNICAL DATA
QRS Sync Output
Delay
Output high
(QRS detected)
Duration
Source impedance
Output low (no QRS)
Pacemaker pulses ≤35 ms
Amplitude: 10 V ±5%
50 ms
5,000 Ω
<0.8 V
Not included
Atmospheric Pressure
Operating
Storage
Protection against
ingress of water
480 to 795 mmHg (64 to 106 kPa)
375 to 795 mmHg (50 to 106 kPa)
IPX1 (per IEC 60529)
Standards
Electrical Specifications
Power source
Input voltage range
Max. power consumption
Patient leakage current
Mode of operation Powered directly from the M540
5 V
≤325 mW under fault condition
≤250 mW during normal operation
≤0.05 mA
Continuous
Physical Specifications
Size (H × W × D)
Weight
Connectors
31 × 66 × 110 mm (1.3 × 2.6 × 4.4 in)
0.19 kg (0.42 lb)
Cable connecting to the M540 Temp/Aux port
IEC 60601-1:2005 + A1:2012: and applicable particular and collateral standards
IEC 60601-1-2:2007: Electromagnetic compatibility
The MCable®-Analog/Sync complies with Medical Devices Directive (MDD)
93/42 EEC and bears the CE mark.
ORDERING INFORMATION
MCable®-Analog/Sync
MS20662
Analog Output Cable, 5 m 4314618
QRS Sync Cable, 3 m 4314667
Order via MS22113
Infinity® is a registered trademark and Acute Care System and MCable® are
trademarks of Dräger Medical.
Environmental Requirements
Temperature Range
Operating
Storage
0°C to 45°C (32°F to 113°F)
-40°C to 70°C (-40°F to 158°F)
Relative Humidity
Operating
Storage
10% to 95%, non-condensing
10% to 95%, condensing
CORPORATE HEADQUARTERS
Drägerwerk AG & Co. KGaA
Moislinger Allee 53–55
23558 Lübeck, Germany
www.draeger.com
Manufacturer:
Draeger Medical Systems, Inc.
3135 Quarry Road
Telford, PA 18969-1042, USA
Locate your Regional Sales
Representative at:
www.draeger.com/contact
REGION EUROPE CENTRAL
AND EUROPE NORTH
REGION MIDDLE EAST, AFRICA
REGION NORTH AMERICA
Drägerwerk AG & Co. KGaA
Moislinger Allee 53–55
23558 Lübeck, Germany
Tel +49 451 882 0
Fax+49 451 882 2080
[email protected]
Drägerwerk AG & Co. KGaA
Branch Office
P.O. Box 505108
Dubai, United Arab Emirates
Tel +971 4 4294 600
Fax+971 4 4294 699
[email protected]
Draeger Medical, Inc.
3135 Quarry Road
Telford, PA 18969-1042, USA
Tel +1 215 721 5400
Toll-free +1 800 437 2437
Fax+1 215 723 5935
[email protected]
REGION EUROPE SOUTH
REGION ASIA / PACIFIC
Dräger Médical S.A.S.
Parc de Haute Technologie
d’Antony 2
25, rue Georges Besse
92182 Antony Cedex, France
Tel +33 1 46 11 56 00
Fax +33 1 40 96 97 20
[email protected]
Draeger Medical
South East Asia Pte Ltd.
25 International Business Park
#04-27/29 German Centre
Singapore 609916, Singapore
Tel +65 6572 4388
Fax+65 6572 4399
[email protected]
REGION CENTRAL
AND SOUTH AMERICA
Dräger Panama Comercial
S. de R.L.
Complejo Business Park,
V tower, 10th floor
Panama City
Tel +507 377 9100
Fax+507 377 9130
[email protected]
90 66 240 | 15.06-5 VG4 | Communications & Sales Marketing | PP | LE | Printed in Germany | Chlorine-free – environmentally compatible | Subject to modifications | © 2015 Drägerwerk AG & Co. KGaA
02 |