Download Voltage Transducer LV 100-1000 V PN = 1000 V

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Spark-gap transmitter wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Decibel wikipedia , lookup

Transformer wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power inverter wikipedia , lookup

Power engineering wikipedia , lookup

Ground (electricity) wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Islanding wikipedia , lookup

Stepper motor wikipedia , lookup

Electrical ballast wikipedia , lookup

Three-phase electric power wikipedia , lookup

Schmitt trigger wikipedia , lookup

Current source wikipedia , lookup

Ohm's law wikipedia , lookup

Triode wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrical substation wikipedia , lookup

Rectifier wikipedia , lookup

Metadyne wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Distribution management system wikipedia , lookup

Power electronics wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power MOSFET wikipedia , lookup

Voltage regulator wikipedia , lookup

Buck converter wikipedia , lookup

Surge protector wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Alternating current wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
Voltage Transducer LV 100-1000
LV 100-1000 BLACKBOX
Only for information. Refer to datasheet
For the electronic measurement of voltages: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
Electrical data
VPN
VPM
IPN
RM
ISN
KN
UC
IC
Features
Primary nominal rms voltage
Primary voltage, measuring range
Primary nominal rms current
Measuring resistance
with ±15 V
VPN = 1000 V
@ ±1000 Vmax
@ ±1500 Vmax
Secondary nominal rms current
Conversion ratio
Supply voltage (±5 %)
Current consumption 1000
0 … ±1500
10
RM min RM max
0
0
210
130
50
1000 V : 50 mA
±15 < 32 + IS
V
V
mA
Ω
Ω
mA
V
mA
Accuracy - Dynamic performance data
XG
Overall accuracy @ VPN, TA = 25 °C
±0.9
εL
Linearity error
< 0.1
Typ
Max
IO
Offset current @ IP = 0, TA = 25 °C
±0.2
IOT
Temperature variation of IO0 °C … +70 °C ±0.2
±0.3
tr
Step response time to 90 % of VPN
110
%
%
mA
mA
µs
General data
TA
Ambient operating temperature
0 … +70
TS
Ambient storage temperature
−25 … +85
NP/NS Turns ratio
10000 : 2000
PP
Total primary power loss
10
R1
Primary resistance
@ TA = 25 °C100
RS
Resistance of secondary winding @ TA = 70 °C
55
m Mass
790
Standard
EN 50178: 1997
°C
°C
W
kΩ
Ω
g
●● Closed loop (compensated)
voltage transducer using the Hall
effect
●● Insulating plastic case recognized
according to UL 94-V0
●● Primary resistor R1 incorporated
within the housing.
LV100-1000 external shape . 06.10.2010 Psa
Advantages
LEM SA
Case Postale 785
CH-1212 Grand-Lancy 1
Geneva, Switzerland
●●
●●
●●
●●
●●
●●
●●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference.
Tel. : +41 22 706 11 11
Fax.: +41 22 794 94 78
www.lem.com
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Uninterruptible Power Supplies
(UPS)
●● Power supplies for welding
applications
Application Domain
●● Industrial.
N° 97.24.60.000.0
21June2016/Version 9
Chemin des Aulx 8
CH-1228 Plan-les-Ouates
Geneva, Switzerland
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Voltage Transducer LV 100-1000
Insulation coordination
Ud
Rms voltage for AC insulation test, 50 Hz, 1 min
ÛW
Impulse withstand voltage 1.2/50 µs
dCp
Creepage distance
dCI
Clearance
CTI
Comparative Tracking Index (group I)
6
12.3
Min
55.12
27.9
600
kV
kV
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
1000 V
1000 V
Reinforced insulation
1000 V
1000 V
dCp, dCI, ÛW
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary connections, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
21June2016/Version 9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Dimensions LV 100-1000 (in mm)
dCI
dCp
Connection
IS
HV
RM
UC
HV
Remarks
Mechanical characteristics
●● General tolerance
●● Transducer fastening
Recommended fastening torque
●● Connection of primary
●● Connection of secondary
●● Connection to the ground
Recommended fastening torque
UC
±0.5 mm
2 holes ⌀ 6.5 mm
2 M6 steel screws
5 N⋅m
M5 threaded studs
Faston 6.3 × 0.8 mm
M5 threaded stud
2.2 N⋅m
●● IS is positive when VP is applied on terminal +HV.
●● The primary circuit of the transducer must be linked
to the connections where the voltage has to be
measured.
●● Installation of the transducer must be done unless
otherwise specified on the datasheet, according to
LEM Transducer Generic Mounting Rules. Please
refer to LEM document N°ANE120504 available on
our Web site: Products/Product Documentation.
●● This is a standard model. For different versions
(supply voltages, turns ratios, unidirectional
measurements...), please contact us.
Page 3/3
21June2016/Version 9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com