Download 1.2 A Programmable Device Power Supply AD5560

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Transcript
AD5560
Data Sheet
Table 21. Compensation Register 2
Address
0x5
Default
0x0110
Bit
15
Name
Manual
compensation
14
13
12
RZ[2:0]
11
10
9
RP[2:0]
8
7
gm[1:0]
Data Bits, MSB First
Function
The AD5560 can be manually configured to compensate the force amplifier into a wide range of load
conditions. When this bit is high, manual compensation mode is active, and it overrides the settings of
Compensation Register 1. Readback when in manual compensation mode returns the compensation
settings loaded to the force amplifier and loaded to this register. Similarly, when in autocompensation
mode, readback of this register address returns the compensation settings of the force amplifier. However,
readback of this register address when in safe mode does not reflect SAFEMODE settings. SAFEMODE
settings are gm[1:0] = 2, RP[2:0] = 0, RZ[2:0] = 0, CC[3:1] = 111, CF[2:0] = 5, and CC0 = 1.
Set the value of RZ to add a zero at the following frequencies. This calculation assumes that CC0 = 100 pF.
RZ
RZx(Ω)
FZ (Hz)
01
500
3.2 M
1
1.6 k
1M
2
5k
320 k
3
16 k
100 k
4
50 k
32 k
5
160 k
10 k
6
500 k
3.2 k
7
1.6 M
1k
Set the value of RP to add an additional pole. There is an internal 8 pF capacitor to provide an RC filter,
creating a pole at one of the following frequencies.
RP[2:0]
RP (Ω)
FP (Hz)
200
100 M
01
1
675
29 M
2
2280
8.7 M
3
7700
2.6 M
4
26 k
760 k
5
88 k
220 k
6
296 k
67 k
7
1M
20 k
Set the transconductance of the force amplifiers input stage. The gain bandwidth (GBW) of the force
voltage loop is equal to gmx/CC0. The following values assume CC0 = 100 pF.
gmx
gmx (µA/V)
GBW (Hz)
0
40
64 k
1
80
130 k
300
480 k (default)
900
1.3 M
1
2
3
6
5
4
CF[2:0]
These bits determine which feedforward capacitor CFx is switched in.
CFx
0
1
2
3
4
Action
None
CF0
CF1
CF2
CF3
CF4
51
6
7
1
None
None
3
CC3
Connect CC3 in series with 100 kΩ1
2
CC2
Connect CC2 in series with 25 kΩ1
1
CC1
0
Reserved
Connect CC1 in series with 6 kΩ1
0
This item corresponds to a SAFEMODE setting (SAFEMODE is the power-on default setting).
Rev. D | Page 50 of 68
Document related concepts

Mains electricity wikipedia, lookup

History of electric power transmission wikipedia, lookup

Power engineering wikipedia, lookup

Buck converter wikipedia, lookup

Switched-mode power supply wikipedia, lookup

Opto-isolator wikipedia, lookup

Current mirror wikipedia, lookup

Alternating current wikipedia, lookup

Voltage optimisation wikipedia, lookup

Power electronics wikipedia, lookup

Voltage regulator wikipedia, lookup

Schmitt trigger wikipedia, lookup

Resistive opto-isolator wikipedia, lookup

Rectifier wikipedia, lookup

Stray voltage wikipedia, lookup

Surge protector wikipedia, lookup

Distribution management system wikipedia, lookup

Current source wikipedia, lookup

Triode wikipedia, lookup

Pulse-width modulation wikipedia, lookup

Variable-frequency drive wikipedia, lookup

Ohm's law wikipedia, lookup

Islanding wikipedia, lookup

Power inverter wikipedia, lookup

Electrical ballast wikipedia, lookup

Electrical substation wikipedia, lookup

Three-phase electric power wikipedia, lookup

Stepper motor wikipedia, lookup

Immunity-aware programming wikipedia, lookup

Wien bridge oscillator wikipedia, lookup

Amplifier wikipedia, lookup

Tube sound wikipedia, lookup

Power MOSFET wikipedia, lookup