1B-289-C025
Monoclonal Antibody to Prostate-specific antigen (PSA)
Biotin conjugated (0.025 mg)
Clone:
A67-B/E3
Isotype:
Mouse IgG1
Specificity:
The antibody A67-B/E3 reacts with prostate-specific antigen (PSA),a protein
produced by normal prostate cells. The highest amounts of PSA are found in the
seminal fluid.
Regulatory Status:
RUO
Immunogen:
30 KDa protein fraction prepared from human seminal plasma
Species Reactivity:
Human
Preparation:
The purified antibody is conjugated with Biotin-LC-NHS under optimum conditions.
The reagent is free of unconjugated biotin.
Concentration:
1 mg/ml
Storage Buffer:
Phosphate buffered saline (PBS) with 15 mM sodium azide, approx. pH 7.4
Storage / Stability:
Store at 2-8oC. Do not freeze. Do not use after expiration date stamped on vial
label.
Usage:
Biotinylated antibody is designed for Western blotting and ELISA.
Suggested working dilution for Western blotting is 1:1000. Indicated dilution is
recommended starting point for use of this product. Working concentrations should
be determined by the investigator.
Expiration:
See vial label
Lot Number:
See vial label
Background:
Prostate-specific antigen (PSA) is a protein produced by normal prostate cells.
This enzyme participates in the dissolution of the seminal fluid coagulum and plays
an important role in fertility. The highest amounts of PSA are found in the seminal
fluid; some PSA escapes the prostate and can be found in the serum. This serum
component has been used to track the response to therapy in men with prostate
cancer.
ISOBM TD-3 PSA Workshop code: 207
References:
*Rye P.D. et al. (Eds.): Summary Report on the ISOBM TD-3 Workshop, Tum.
Biol. 20 (S1), pp 1-94 (1999).
Unless indicated otherwise, all products are For Research Use Only and not for diagnostic or therapeutic use. Not for resale or transfer
either as a stand-alone product or as a component of another product without written consent of EXBIO. EXBIO will not be held
responsible for patent infringement or other violations that may occur with the use of our products. All orders are accepted subject to
EXBIO´s term and conditions which are available at www.exbio.cz.
For laboratory research only, not for drug, diagnostic or other use.