Download Electronic Ballasts - Ultra Violet Products

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stray voltage wikipedia , lookup

Power engineering wikipedia , lookup

Electrical substation wikipedia , lookup

Control system wikipedia , lookup

Electrical engineering wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switch wikipedia , lookup

Electronic engineering wikipedia , lookup

Buck converter wikipedia , lookup

Electrification wikipedia , lookup

Opto-isolator wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electronic musical instrument wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Music technology (electronic and digital) wikipedia , lookup

Metadyne wikipedia , lookup

Electronic paper wikipedia , lookup

Automotive lighting wikipedia , lookup

Electronic music wikipedia , lookup

Mains electricity wikipedia , lookup

Rectiverter wikipedia , lookup

LED lamp wikipedia , lookup

Fluorescent lamp wikipedia , lookup

Safety lamp wikipedia , lookup

Oil lamp wikipedia , lookup

Electrical ballast wikipedia , lookup

Transcript
Electronic Ballasts
for the Amalgam
Ultra Violet Lamps
The UVP range of electronic ballasts have being specifically designed to operate our range of Standard, High Output
and Amalgam, Low-Pressure Mercury Vapour Lamps, driving them at their optimum performance, but will also run any
other brands of low-pressure mercury vapour lamps given their operating characteristics match that of the
appropriate UVP electronic ballast. Because these electronic ballasts operate at High Frequency, (Up to 50 KHz, as
opposed to the electrical mains supply of 50 Hz) the length of electrical cable from the electronic ballast to the Ultra
Violet Lamp MUST be no more than 30 m for the Standard range of UV lamps, and 15 m for the Amalgam range of UV
lamps. When installing the electronic ballast(s), they MUST be mounted upright with the mains terminals at the
bottom, and be at least 100 mm apart, in all directions, to allow for the required cooling effects as the electronic
ballasts emit heat through the case. Therefore, unless there is sufficient means for cooling, the electronic ballast(s)
cannot be installed in airtight enclosures. The Electronic Ballast’s Case MUST be correctly Earthed. The electronic
ballasts are guaranteed against faulty parts and/or workmanship for a period of 2-years from the date of delivery.
Important Safety Notice:
Risk of Electric Shock! Potentially Lethal high voltages occur inside the electronic ballast and at the ballast terminals.
Please refer to the safety rules in the UVP Installation and Operation Instructions sheet.
16
15
14
13
12 11 10
LAMP FAULT
CONTACTS
LAMP
8 to10 mm
Green and
Red LED
Indicator Lights
8.06 mm
0.75 ... 1.5 mm2
UVP-3500/5700-500-A90
Electronic Ballast for the High
Output Range of Amalgam Lamps
For Pre-Heat Amalgam Lamps
Input Voltage:
Input Current:
240V 50Hz
Max 2.80A
Lamp Power: 250 - 500W
Lamp Current: 3.5 - 5.7A
DIP Switch Settings
Running Current
Wattage
Example Lamp Types
3.5 to 3.8
250 to 350
G60T32N A90 SE4P
4.6 to 5.0
320 to 400
G60T32N A90 SE4P HO
5.3 to 5.7
400 to 500
G60T38N A90 SE4P
Settings
Ambient Temperature: -15 to 400C
Disconnect the Incoming 230 - 240V Power Supply before
Installing or Servicing this Ballast
tc = max 700C
Ballast Case MUST be Earthed
.
Position
1
0
1 2 3 4 5 6 7 8
6
7
8
9
485
A
5
485 -
N
4
485 +
E
DIP Switch Setting - No. 8
For Remote Control Set to 0
For Local Control Set to 1
485
3
485 -
2
485 +
1
The UVP electronic ballasts have being designed with the capability of running either Pre-Heat, Bi-pin
lamps, (whether they be two pins at each end, or four pins at one end) or Instant Start, single pin
lamps. (whether they be single pin at each end, or two pins at one end) The wiring configuration is
shown in the wiring diagram below. Due to the High In-Rush Current, the mains electrical wiring cable
to the electronic ballast should have a cross-sectional area greater than 0.75 mm2 to 1.5 mm2.
5
485 -
4
485 +
1
0
A
N
E
3
1 2 3 4 5 6 7 8
9
8
7
6
485
DIP Switch Setting - No. 8
For Remote Control Set to 0
For Local Control Set to 1
485 +
2
G60T38N A90 SE4P
400 to 500
5.3 to 5.7
485 -
1
G60T32N A90 SE4P HO
320 to 400
4.6 to 5.0
.
G60T32N A90 SE4P
Input Voltage:
Input Current:
LAMP
190 mm
57 mm
Ambient Temperature: -15 to 400C
Disconnect the Incoming 230 - 240V Power Supply before
Installing or Servicing this Ballast
tc = max 700C
Ballast Case MUST be Earthed
Settings
Example Lamp Types
250 to 350
3.5 to 3.8
DIP Switch Settings
Wattage
Running Current
Lamp Power: 250 - 500W
Lamp Current: 3.5 - 5.7A
240V 50Hz
Max 2.80A
Green and
Red LED
Indicator Lights
LAMP FAULT
CONTACTS
12 11 10
16
15
14
13
140 mm
250 mm
485
Position
For Pre-Heat Amalgam Lamps
Phone: 61 03 6239 3355
Fax: 61 03 6239 3455
Email: [email protected]
UVP-3500/5700-500-A90
Electronic Ballast for the High
Output Range of Amalgam Lamps
Phone: 61 08 8351 2822
Fax: 61 08 8351 2811
Email: [email protected]
0.75 ... 1.5 mm2
76 Diamond Drive
Blackmans Bay, Tasmania
AUSTRALIA 7052
8 to10 mm
15 Marlow Road
Keswick, South Australia
AUSTRALIA 5025
1 2 3 4 5 6 7 8
Ultra Violet Products (Aust) Pty Ltd