Download Sunny Tripower 60-US

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

IEEE 1355 wikipedia , lookup

Power over Ethernet wikipedia , lookup

Transcript
stp60-us-10
sunny tRIpowER 60-us
Efficient
Reliable
Cost-Effective
Innovative
•Maximumefficiencyof98.8%
•Superiorpowerdensity:
60kVAatonly165pounds
•Distributedarchitectureformaximumsystemavailability
•CentralcontrolwithSMAInverter
Manager
•DCinputofupto1,000V
•Upto2.5MWperinvertermanager
•Suitableforcommercialandutility
applications
•Completegridmanagementfeatureset
sunny tRIpowER 60-us
The efficient solution for medium to large-scale PV Plants
ThenewSunnyTripower60-USispartofaninnovative,globalsystemsolutionforcommercialandutilityPVplants.Thissolutioncombinestheadvantagesofadecentralizedsystemlayoutwiththebenefitsofcentralizedinverterdesignswhichresultsin
thebestofbothworlds.Highefficiency,easyinstallation,simplecommissioningandlowmaintenancerequirementscontribute
decisivelytoreducingtheoperatingcostsfortheentireplant.
thE smaRt sunny tRIpowER 60-us systEm phIlosophy
unmatChEd
powER dEnsIty
With Maximum E ciency
The new SMA system solution consists of
three components: highly e cient Sunny
Tripower60-USinverters,theSMAInverter
ManagerandtheLCScommissioningtool.
It is precisely this systemized approach
that makes the Sunny Tripower 60-US so
uniqueandensuresahighlevelofperformance.
system Cost Reduction
Withacompactdesignof60kVAweighingonly165pounds,theSunnyTripower
60-USrequireslittlespace,reduceson-site
preparation work, simpli es installation
andlowersmaintenancecosts.
Innovative system management
The SMA Inverter Manager is the central
communicationscomponentandsoleinterfacefortheentiresystemcontrol.Ithandles
alltheimportantinverterandsystemmanagementfunctionsforupto2.5MWwith
asingleinvertermanager.
TheSunnyTripower60-USbene tsfroma
self-con guring inverter network with automaticIPcon gurationanddevicediscovery,
whicheliminatesmanualsetup.TheSMAInverterManageralsocreatesaseamlessinvertercontrolloopwhichenablescomplete
gridmanagementcapabilities.
simple commissioning
The specially developed LCS tool (Local
Commissioning and Service Tool) makes
commissioningeasy,savestimeandreducescosts.Theinverteriscon guredbysimply
selecting the system-speci c con guration
lesandthentransmittingthemtoallinverters. In addition, individual inverter data is
aggregated into a single plant pro le for
comprehensiveplantperformanceanalysis.
technical data
sunny tripower 60-us
&GGJDJFODZDVSWF4VOOZ5SJQPXFS64
1,000V
570Vto800V@400VAC,685Vto800V@480VAC
565V@400VAC,680V@480VAC
110A/150A
1/1(splitupbyexternalPVarrayjunctionbox)
60,000W
60,000VA
3/PE
400V,480V
352Vto440V@400VAC,423Vto528V@480VAC
50Hz,60Hz
50Hz,60Hz/400V,480V
3x87A@400V,3x72A@480V
1/0.8lagging...0.8leading
3/3
98.8%/98.0%/98.5%
●/●
●/●
●/●/—
●
I/AC:III,DC:II
570/740/300mm(22.4/29.1/11.8inch)/75kg(165.3lbs)
-25°C...+60°C(-13°Fto+140°F)
55dB(A)/3W
Transformerless/active,IP65/NEMA3R,4K4H
95%
Screwterminal/screwterminal
Graphic/Usingexternalinvertermanager:ModbusTCP
type designation
SunnyTripower60-US:
STP60-US-10withDCSwitch
SMAInverterManager:
IM-10:SMAInverterManagerformax.42inverters
I/OModule:
IM-DIO-10:SMADigitalI/OBoxwith6digitalinputs
Certi cates and Approvals
SunnyTripower60-US:IEC62109-1/IEC62109-2(ClassI,grounded—
communicationClassII,PELV),UL1741—w.Non-IsolatedEPSInteractivePV
Inverters,IEEE1547,FCCPart15,SubpartBClassA
SMAInverterManager:UL508,UL60950-1,CSAC22.2No.60950-1-07,
EN60950-1,EN55022ClassA,EN61000-3-2ClassD,EN61000-3-3,
EN55024,FCCPart15,SubpartBClassA
technical data
Voltage supply
Inputvoltage
Powerconsumption
General data
Dimensions(W/H/D)/weight
Degreeofprotection/assembly
Operatingtemperaturerange/relativehumidity
Coolingconcept
Interfaces
Userinterface/Sensorinterface
Activeandreactivepowersetpoints
Interfacetoinverternetwork/Interfacetoexternalnetwork
Interfacetoremotecontrol
Dataatnominalconditions
+1 888 476 2872
www.sma-america.com
sma Inverter manager
9-36Vdc
<20W
160/125/49mm(6.3/4.9/1.9inch)/940g(2lbs)
IP21/DINtop-hatrailsorwallmounting
-40to+85°C/5-95%(non-condensing)
Convection
LCStoolforPC/RS-485forSunspecAlliancecompatibleweatherstations
Constantvalues,curves,remotelycontrolled
1Ethernetport(RJ45)/1Ethernetport(RJ45)ModbusTCP,SunSpecAlliance
6xDI,ModbusTCPviaexternalI/Omodule
sma america, llC
STP60-US-DUS151619SMAandSunnyTripowerareregisteredtrademarksofSMASolarTechnologyAG.PrintedonFSC-certi edpaper.Allproductsandservicesdescribedaswellastechnicaldata
aresubjecttochange,evenforreasonsofcountry-speci cdeviations,atanytimewithoutnotice.SMAassumesnoliabilityforerrorsoromissions.Forcurrentinformation,seewww.SMA-Solar.com.
Input (dC)
Max.inputvoltage
MPPvoltagerange
Min.inputvoltage
Max.inputcurrent/short-circuitcurrent
NumberofindependentMPPinputs/stringsperMPPinput
output (aC)
Ratedpoweratnominalvoltage
Max.apparentACpower
OutputPhases/lineconnections
NominalACvoltage
NominalACvoltagerange
ACpowerfrequency
Ratedpowerfrequency/ratedgridvoltage
Max.outputcurrent
Powerfactoratratedpower/displacementpowerfactoradjustable
Feed-inphases/connectionphases
E ciency
Max.e ciency/CEC@400VAC/CEC@480VAC
protective devices
DC-sidedisconnectionpoint/DCsurgearrester(typeII)canbeintegrated
Groundfaultmonitoring/gridmonitoring
DCreversepolarityprotection/ACshort-circuitcurrentcapability/galvanicallyisolated
All-polesensitiveresidual-currentmonitoringunit
Protectionclass(acc.toIEC62103)/overvoltagecategory(acc.toIEC60664-1)
General data
Dimensions(W/H/D)/weight
Operatingtemperaturerange
Noiseemission,typical/Self-consumption(atnight)
Topology/coolingconcept,degreeofprotect.(IEC60529/UL50E),climaticcat.(IEC60721-3-4)
Maximumpermissiblevalueforrelativehumidity(non-condensing)
Features
DCconnection/ACconnection
Display/Interface
●Standardfeatures ○Optionalfeatures —Notavailable