HALOFIX 90 50 V/AC (75 V/DC)
Heat resistant light flat flexible cord
RATED VOLTAGE
IDENTIFICATION OF CORES
U = 50 V (AC), 75 V (DC)
One conductor identified by a longitudinal ridge.
This cable is possible to have with white (VA)
or black (MU) colour.
APPLICATION
For fixed installation as connection cords for minivoltage
halogen lights in domestic premises, offices and as
loudspeaker cables in sound systems.
STANDARDS
When used in connection with electronic transformers the
maximum recommended cord length is 2 meters.
IEC / EN 60332-1
General guide to use and current carrying capacities according
to SFS 6000.
EN 50525-2-11 when applicable
CERTIFICATES, APPROVALS
The cable does not contain any substances on the
REACH/SVHC -list.
Highest permissible conductor temperature:
• continuous operation
• short circuit (duration up to 5 s)
90 °C
150 °C
All substances of the cable meet the requirements of
RoHS directive.
Lowest recommended temperature
during laying: (3)
-15 °C
CUSTOMS CODE
Maximum permissible pulling force from conductor
is 15x A N/mm2
8544 49 93
CONSTRUCTION
Conductor Stranded flexible copper wire
Insulation Lead-free heat resistant PVC compound,
two conductors parallel
23.07.2014 © Prysmian Group. All rights reserved.
All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group; any modification or alteration
afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent
of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without notice.
This specification is not contractually valid unless specifically authorised by Prysmian Group.
Flexible cords
HALOFIX 90 50 V/AC (75 V/DC)
PROPERTIES
HALOFIX 90
2X1,5 VA
PRODUCT NAME
HALOFIX 90
2X1,5 MU
PE1/50
0232091
STK-code and spool type
HALOFIX 90
2X2,5 VA
HALOFIX 90
2X2,5 MU
P2/50
0232092
HALOFIX 90
2X6 VA
HALOFIX 90
2X6 MU
P2/50
0232096
P2/50
0232089
ProPac 200
0232085
ProPac 200
0232087
ProPac 150
0232086
ProPac 150
0232088
3,2x6,8
3,2x6,8
3,7x7,8
3,7x7,8
5,6x12
5,6x12
kg/km
45
45
65
65
150
150
mm
10
10
15
15
20
20
Ω/km
13,3
13,3
7,98
7,98
3,30
3,30
A
17,5
17,5
24
24
40
40
STK-code, ProPac
CONSTRUCTION DATA (1)
Diameter over cable
Weight
mm
MECHANICAL DATA (2)
Minimum permissible bending radius
at final installation (3)
ELECTRICAL DATA (2)
Maximum DC resistance,
conductor 20°C
CURRENT RATINGS (2) (4)
Reference installation type B
(1) Approximate value.
(2) See the basic assumptions at general information of products.
(3) Final installation with careful single bending into final position.
(4) Other installation types, see SFS 6000-5.
23.07.2014 © Prysmian Group. All rights reserved.
All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group; any
modification or alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in
part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian