Velleman Inc.
... function generator: crystal-based stability standard waveforms: sine, square and triangle predefined library waveforms included: sine(x)/x, DCV, sweep, ... oscilloscope: auto set-up function and X10 option pre-trigger function readouts: True RMS, dBV, dBm, p to p, Duty cycle, Frequency… transient ...
... function generator: crystal-based stability standard waveforms: sine, square and triangle predefined library waveforms included: sine(x)/x, DCV, sweep, ... oscilloscope: auto set-up function and X10 option pre-trigger function readouts: True RMS, dBV, dBm, p to p, Duty cycle, Frequency… transient ...
Electronics Manual
... Part 2: To measure the amplitude and frequency of an AC signal The signal to be investigated is that produced by the variable frequency signal generator. Output sockets, one of which is earthed, are at the lower right of the panel. The knob below the dial knob is the frequency range selector switch ...
... Part 2: To measure the amplitude and frequency of an AC signal The signal to be investigated is that produced by the variable frequency signal generator. Output sockets, one of which is earthed, are at the lower right of the panel. The knob below the dial knob is the frequency range selector switch ...
Experiment 4 Cathode Ray Oscilloscope and Multimeter
... tool in studying time-variant inputs, such as alterCω nating current,modulated signals etc..itconsists of an Xl = Lω (2b) electron beam which when incident on the phosphor screen produces a glowing dot.When a transverse The Multimeter is used to verify the data collected Electric field is applied th ...
... tool in studying time-variant inputs, such as alterCω nating current,modulated signals etc..itconsists of an Xl = Lω (2b) electron beam which when incident on the phosphor screen produces a glowing dot.When a transverse The Multimeter is used to verify the data collected Electric field is applied th ...
service scope
... you return the unit to Tektronix for service. If you have occasion to align the RF section of the analyzer, you will encounter a spurious that occurs at about 12.5 MHz. This can be tuned down by inserting an RF signal close to it in frequency. With both the signal and spurious displayed on screen, s ...
... you return the unit to Tektronix for service. If you have occasion to align the RF section of the analyzer, you will encounter a spurious that occurs at about 12.5 MHz. This can be tuned down by inserting an RF signal close to it in frequency. With both the signal and spurious displayed on screen, s ...
β τ β - Hacettepe University, Department of Electrical and Electronics
... with a constant speed. The period of time taken to cause the spot to deflect across the face of the fluorescent screen is known as the sweep time. When the spot reaches the right hand side of the tube, it must immediately return to the left hand side and start tracing again. Initially the time base ...
... with a constant speed. The period of time taken to cause the spot to deflect across the face of the fluorescent screen is known as the sweep time. When the spot reaches the right hand side of the tube, it must immediately return to the left hand side and start tracing again. Initially the time base ...
Oscilloscope history
This article discusses the history and development of oscilloscope technology.