tb70.pdf
... 85 ps with a 2× frequency average of 100.073 MHz. The jitter distribution of the measured periods had four distinct peaks, indicating that four different fundamental periods are used in succession to achieve an average period of 10 ns. This excessive amount of jitter adversely affects system perform ...
... 85 ps with a 2× frequency average of 100.073 MHz. The jitter distribution of the measured periods had four distinct peaks, indicating that four different fundamental periods are used in succession to achieve an average period of 10 ns. This excessive amount of jitter adversely affects system perform ...
Frequency Inverter CFW100 V2.3X
... 11.2.3 Output Current Limitation by “Ramp Hold” P150 = 2 or 3:...........................................11-5 11.2.4 Current Limitation Type “Decelerate Ramp” P150 = 0 or 1:.........................................11-5 ...
... 11.2.3 Output Current Limitation by “Ramp Hold” P150 = 2 or 3:...........................................11-5 11.2.4 Current Limitation Type “Decelerate Ramp” P150 = 0 or 1:.........................................11-5 ...
差分放大器系列AD8336 数据手册DataSheet 下载
... differential gain control interface provides precise linear-in-dB gain scaling of 50 dB/V over the temperature span of −55°C to +125 °C. The differential gain control is easy to interface with a variety of external circuits within the common-mode voltage limits of the AD8336. ...
... differential gain control interface provides precise linear-in-dB gain scaling of 50 dB/V over the temperature span of −55°C to +125 °C. The differential gain control is easy to interface with a variety of external circuits within the common-mode voltage limits of the AD8336. ...
N3 Instruction Manual
... z To avoid the front cover from disengaging or other damage, do not carry the inverter by its cover. Support the drive by its heat sink when transporting. Improper handling can damage the inverter or injure personnel, and should be avoided. z To avoid the risk of fire, do not install the inverter on ...
... z To avoid the front cover from disengaging or other damage, do not carry the inverter by its cover. Support the drive by its heat sink when transporting. Improper handling can damage the inverter or injure personnel, and should be avoided. z To avoid the risk of fire, do not install the inverter on ...
A Linguistically Grounded Annotation Language for Spatial
... 1. Introduction to the Problem The automatic recognition of spatial information in natural language is currently an area of considerable attention in computational linguistics and Artificial Intelligence. The development of algorithms that exhibit “spatial awareness” promises to add needed functiona ...
... 1. Introduction to the Problem The automatic recognition of spatial information in natural language is currently an area of considerable attention in computational linguistics and Artificial Intelligence. The development of algorithms that exhibit “spatial awareness” promises to add needed functiona ...
Glossary of Terms Used in NERC Reliability Standards
... restoration plan needs for Real and Reactive Power capability, frequency and voltage control, and that has been included in the Transmission Operator’s restoration plan. A set of dispatch rules such that given a specific amount of load to serve, an approximate generation dispatch can be determined. ...
... restoration plan needs for Real and Reactive Power capability, frequency and voltage control, and that has been included in the Transmission Operator’s restoration plan. A set of dispatch rules such that given a specific amount of load to serve, an approximate generation dispatch can be determined. ...